The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Young’s double-slit experiment with atoms: A simple atom interferometer
Abstract
An atomic interferometer based on a Young's-type double-slit arrangement has been demonstrated. A supersonic beam of metastable helium atoms passes through a 2-\ensuremath{\mu}m-wide slit in a thin gold foil. This transversely coherent beam impinges on a second microfabricated transmission structure, consisting of two 1-\ensuremath{\mu}m-wide slits at a lateral distance of 8 \ensuremath{\mu}m. This double slit defines two possible paths on which the atoms can reach the detector slit. The good visibility of the observed fringes should make it possible to measure differential phase shifts in the interferometer of 1/3 rad in less than 10 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic interferometry with internal state labelling
Bordé, C. J. (1989) · Physics Letters A · doi:10.1016/0375-9601(89)90537-9 · Cited by 535
Bragg scattering of atoms from a standing light wave
Martin, P., Oldaker, B., Miklich, A., & Pritchard, D. (1988) · Physical Review Letters · doi:10.1103/physrevlett.60.515 · Cited by 378
Single- and double-slit diffraction of neutrons
Zeilinger, A., Gähler, R., Shull, C. G., Treimer, W., & Mampe, W. (1988) · Reviews of Modern Physics · doi:10.1103/revmodphys.60.1067 · Cited by 323
Diffraction of Atoms by a Transmission Grating
Keith, D. W., Schattenburg, M. L., Smith, H. I., & Pritchard, D. E. (1988) · Physical Review Letters · doi:10.1103/physrevlett.61.1580 · Cited by 197
Ultra-high sensitivity accelerometers and gyroscopes using neutral atom matter-wave interferometry
Clauser, J. F. (1988) · Physica B+C · doi:10.1016/0378-4363(88)90176-3 · Cited by 166
Is spin coherence like Humpty-Dumpty?
Schwinger, J., Scully, M. O., & Englert, B. (1988) · Zeitschrift für Physik D Atoms Molecules and Clusters · doi:10.1007/bf01384847 · Cited by 96
Cited by
Optics and interferometry with atoms and molecules
Cronin, A. D., Schmiedmayer, J., & Pritchard, D. E. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1051 · Cited by 1,420
Atomic interferometry using stimulated Raman transitions
Kasevich, M., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.181 · Cited by 1,377
A “Schrödinger Cat” Superposition State of an Atom
Monroe, C., Meekhof, D. M., King, B. E., & Wineland, D. J. (1996) · Science · doi:10.1126/science.272.5265.1131 · Cited by 1,313
High-precision gravity measurements using atom interferometry
Peters, A., Chung, K. Y., & Chu, S. (2001) · Metrologia · doi:10.1088/0026-1394/38/1/4 · Cited by 965
Nobel Lecture: The manipulation of neutral particles
Chu, S. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.685 · Cited by 919
Electromagnetically induced transparency
Marangos, J. P. (1998) · Journal of Modern Optics · doi:10.1080/09500349808231909 · Cited by 745
Brune, M., Haroche, S., Raimond, J. M., Davidovich, L., & Zagury, N. (1992) · Physical Review A · doi:10.1103/physreva.45.5193 · Cited by 737
Quantum Walk in Position Space with Single Optically Trapped Atoms
Karski, M., Förster, L., Choi, J.-M., Steffen, A., Alt, W., Meschede, D., & Widera, A. (2009) · Science · doi:10.1126/science.1174436 · Cited by 659
Keith, D. W., Ekstrom, C. R., Turchette, Q. A., & Pritchard, D. E. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.2693 · Cited by 582
Laser cooling and trapping of neutral atoms
Adams, C. S., & Riis, E. (1997) · Progress in Quantum Electronics · doi:10.1016/s0079-6727(96)00006-7 · Cited by 557
Measurement of the gravitational acceleration of an atom with a light-pulse atom interferometer
Kasevich, M., & Chu, S. (1992) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00325375 · Cited by 550
Optical Ramsey spectroscopy in a rotating frame: Sagnac effect in a matter-wave interferometer
Riehle, F., Kisters, T., Witte, A., Helmcke, J., & Bordé, C. J. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.177 · Cited by 541
Adams, C. S., Sigel, M., & Mlynek, J. (1994) · Physics Reports · doi:10.1016/0370-1573(94)90066-3 · Cited by 523
Self-citationLaser Manipulation of Atoms and Particles
Chu, S. (1991) · Science · doi:10.1126/science.253.5022.861 · Cited by 390
Six-Axis Inertial Sensor Using Cold-Atom Interferometry
Canuel, B., Leduc, F., Holleville, D., Gauguet, A., Fils, J., Virdis, A., Clairon, A., Dimarcq, N., Bordé, C. J., Landragin, A., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.010402 · Cited by 387
Quantum interference of large organic molecules
Gerlich, S., Eibenberger, S., Tomandl, M., Nimmrichter, S., Hornberger, K., Fagan, P. J., Tüxen, J., Mayor, M., & Arndt, M. (2011) · Nature Communications · doi:10.1038/ncomms1263 · Cited by 385
Atom Michelson Interferometer on a Chip Using a Bose-Einstein Condensate
Wang, Y.-J., Anderson, D. Z., Bright, V. M., Cornell, E. A., Diot, Q., Kishimoto, T., Prentiss, M., Saravanan, R. A., Segal, S. R., & Wu, S. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.090405 · Cited by 384
Taking atom interferometric quantum sensors from the laboratory to real-world applications
Bongs, K., Holynski, M., Vovrosh, J., Bouyer, P., Condon, G., Rasel, E., Schubert, C., Schleich, W. P., & Roura, A. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0117-4 · Cited by 382
Complex wave-field reconstruction using phase-space tomography
Raymer, M. G., Beck, M., & McAlister, D. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.1137 · Cited by 348
Correlations and Counting Statistics of an Atom Laser
Öttl, A., Ritter, S., Köhl, M., & Esslinger, T. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.090404 · Cited by 328
Double-slit interference with Laguerre-Gaussian beams
Sztul, H. I., & Alfano, R. R. (2006) · Optics Letters · doi:10.1364/ol.31.000999 · Cited by 309
Exploring gravity with the MIGA large scale atom interferometer
Canuel, B., Bertoldi, A., Amand, L., Pozzo di Borgo, E., Chantrait, T., Danquigny, C., Dovale Álvarez, M., Fang, B., Freise, A., Geiger, R., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32165-z · Cited by 285
Measurement of the Wigner function of an ensemble of helium atoms
Kurtsiefer, C., Pfau, T., & Mlynek, J. (1997) · Nature · doi:10.1038/386150a0 · Cited by 280
Self-citationQuantum interference experiments with large molecules
Nairz, O., Arndt, M., & Zeilinger, A. (2003) · American Journal of Physics · doi:10.1119/1.1531580 · Cited by 254
Coherent atomic mirrors and beam splitters by adiabatic passage in multilevel systems
Marte, P., Zoller, P., & Hall, J. L. (1991) · Physical Review A · doi:10.1103/physreva.44.r4118 · Cited by 253
A survey of quantum-like approaches to decision making and cognition
Ashtiani, M., & Azgomi, M. A. (2015) · Mathematical Social Sciences · doi:10.1016/j.mathsocsci.2015.02.004 · Cited by 96
Hong–Ou–Mandel interference of two independent continuous-wave coherent photons
Kim, H., Kim, D., Park, J., & Moon, H. S. (2020) · Photonics Research · doi:10.1364/prj.393246 · Cited by 20
Metadata
- Authors
- Carnal, O., & Mlynek, J.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1991-05-27
- Volume
- 66
- Issue
- 21
- Pages
- 2689-2692
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W1983175027
- Cited by
- 626
- References
- 6
- FWCI
- 20.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.