Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 752

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Generation of Coherent Soft X Rays at 2.7 nm Using High Harmonics

Chang, Zenghu, Rundquist, Andy, Wang, Haiwen, Murnane, Margaret M., Kapteyn, Henry C.·1997·Physical Review Letters

Abstract

Ultrafast laser pulses from a Ti:sapphire laser centered at 800 nm, with 26 fs pulse duration, were used to generate coherent soft-x-ray harmonics, at wavelengths down to 2.7 nm (460 eV) in He, and 5.2 nm (239 eV) in Ne. In He, discrete harmonic peaks are observed up to order 221, and unresolved harmonic emission is observed up to order 297. These wavelengths are well within the ``water window'' region of x-ray transmission. Our work represents the shortest wavelength coherent light generated to date. The harmonic cutoff from all the noble gases is consistent with analytic theory.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.79.2967

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 752

Metadata

Authors
Chang, Z., Rundquist, A., Wang, H., Murnane, M. M., & Kapteyn, H. C.
Venue
Physical Review Letters
Published
1997-10-20
Volume
79
Issue
16
Pages
2967-2970
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W1995846675
Cited by
752
References
1
FWCI
30.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Generation of Coherent Soft X Rays at 2.7 nm Using High Harmonics. https://app.cochat.ai/papers/10.1103/physrevlett.79.2967
The paper
Chang, Z., Rundquist, A., Wang, H., Murnane, M. M., & Kapteyn, H. C. (1997). Generation of Coherent Soft X Rays at 2.7 nm Using High Harmonics. Physical Review Letters. https://doi.org/10.1103/physrevlett.79.2967

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.