The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Laser-Cooled Mercury Ion Frequency Standard
Abstract
A stable and accurate frequency standard based on the 40.5 GHz ground-state hyperfine transition in ${}^{199}{\mathrm{Hg}}^{+}$ ions is described. The ions are confined in a cryogenic linear Paul (rf) trap and laser cooled to form a linear crystal. With seven ions and a Ramsey interrogation time of 100 s, the fractional frequency stability is 3.3 $(2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$ for measurement times $\ensuremath{\tau}<2\phantom{\rule{0ex}{0ex}}\mathrm{h}$. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in the parentheses is the uncertainty due to statistical and systematic effects, and the second is the uncertainty in the frequency of the time scale to which our standard is compared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Self-citation
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Atomic clocks based on coherent population trapping: a review
Vanier, J. (2005) · Applied Physics B · doi:10.1007/s00340-005-1905-3 · Cited by 669
High-Fidelity Preparation, Gates, Memory, and Readout of a Trapped-Ion Quantum Bit
Harty, T. P., Allcock, D. T. C., Ballance, C. J., Guidoni, L., Janacek, H. A., Linke, N. M., Stacey, D. N., & Lucas, D. M. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.220501 · Cited by 632
Visible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
Self-citationQuantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard
Santarelli, G., Laurent, P., Lemonde, P., Clairon, A., Mann, A. G., Chang, S., Luiten, A. N., & Salomon, C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4619 · Cited by 569
Metadata
- Authors
- Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1998-03-09
- Volume
- 80
- Issue
- 10
- Pages
- 2089-2092
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2495554234
- Cited by
- 196
- References
- 1
- FWCI
- 10.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laser-Cooled Mercury Ion Frequency Standard. https://app.cochat.ai/papers/10.1103/physrevlett.80.2089
- The paper
- Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998). Laser-Cooled Mercury Ion Frequency Standard. Physical Review Letters. https://doi.org/10.1103/physrevlett.80.2089
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.