The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Three-Dimensional Vibrational Imaging by Coherent Anti-Stokes Raman Scattering
Abstract
A multiphoton microscopy based on coherent anti-Stokes Raman scattering is accomplished with near-infrared ultrashort laser pulses. We demonstrate vibrational imaging of chemical and biological samples with high sensitivity, high spatial resolution, noninvasiveness, and three-dimensional sectioning capability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
The Principles of Nonlinear Optics
Shen, Y. R. (1984) · Cited by 5,211
The Principles of Nonlinear Optics
Welford, W. T. (1985) · Physics Bulletin · doi:10.1088/0031-9112/36/4/046 · Cited by 2,245
Infrared and Raman Spectroscopy: Methods and Applications
(1995) · Wiley eBooks · doi:10.1002/9783527615438 · Cited by 1,135
Studying single living cells and chromosomes by confocal Raman microspectroscopy
Puppels, G. J., de Mul, F. F. M., Otto, C., Greve, J., Robert-Nicoud, M., Arndt-Jovin, D. J., & Jovin, T. M. (1990) · Nature · doi:10.1038/347301a0 · Cited by 920
Fredrickson, J. K., Zachara, J. M., Kennedy, D. W., Dong, H., Onstott, T. C., Hinman, N. W., & Li, S.-M. (1998) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(98)00243-9 · Cited by 807
Scanning coherent anti-Stokes Raman microscope
Duncan, M. D., Reintjes, J., & Manuccia, T. J. (1982) · Optics Letters · doi:10.1364/ol.7.000350 · Cited by 626
Nonlinear scanning laser microscopy by third harmonic generation
Barad, Y., Eisenberg, H., Horowitz, M., & Silberberg, Y. (1997) · Applied Physics Letters · doi:10.1063/1.118442 · Cited by 607
3D microscopy of transparent objects using third‐harmonic generation
Müller, Squier, Wilson, & Brakenhoff (1998) · Journal of Microscopy · doi:10.1046/j.1365-2818.1998.00399.x · Cited by 308
Seeing the Machinery of Live Cells
Tsien, R. Y., & Miyawak, A. (1998) · Science · doi:10.1126/science.280.5371.1954 · Cited by 183
Image formation in two-photon fluorescence microscopy
Sheppard, C. J. R., & Gu, M. (1990) · Optik · Cited by 132
High-repetition-rate femtosecond optical parametric oscillator–amplifier system near 3 μm
Holtom, G. R., Crowell, R. A., & Xie, X. (1995) · Journal of the Optical Society of America B · doi:10.1364/josab.12.001723 · Cited by 32
Self-citation
Cited by
Novotny, L., & Hecht, B. (2025) · Cambridge University Press eBooks · doi:10.1017/9781108781503 · Cited by 6,220
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Label-Free Biomedical Imaging with High Sensitivity by Stimulated Raman Scattering Microscopy
Freudiger, C. W., Min, W., Saar, B. G., Lu, S., Holtom, G. R., He, C., Tsai, J. C., Kang, J. X., & Xie, X. S. (2008) · Science · doi:10.1126/science.1165758 · Cited by 2,255
Self-citationGustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Ultrasensitive Chemical Analysis by Raman Spectroscopy
Kneipp, K., Kneipp, H., Itzkan, I., Dasari, R. R., & Feld, M. S. (1999) · Chemical Reviews · doi:10.1021/cr980133r · Cited by 2,181
Metadata
- Authors
- Zumbusch, A., Holtom, G. R., & Xie, X. S.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1999-05-17
- Volume
- 82
- Issue
- 20
- Pages
- 4142-4145
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2104460891
- Cited by
- 1,626
- References
- 12
- FWCI
- 13.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.