Cold Collision Frequency Shifts in a87RbAtomic Fountain
The DOI matches its Crossref record.
Abstract
We present measurements of cavity frequency pulling and collisional frequency shifts in a ${}^{87}\mathrm{Rb}$ fountain with a frequency resolution of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$. Agreement with theory is found for the cavity pulling and the measured collisional shifts. The clock shift is found at least $50$ times smaller than in ${}^{133}\mathrm{Cs}$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Wynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Self-citationProgress in atomic fountains at LNE-SYRTE
Guena, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Self-citationMaking, probing and understanding ultracold Fermi gases
Ketterle, W., & Zwierlein, M. W. (2008) · arXiv (Cornell University) · doi:10.48550/arxiv.0801.2500 · Cited by 239
“Indeed, they are one of the dominant sources of systematic error in current cold atom fountain clocks [126].”
BackgroundHarber, D. M., Lewandowski, H. J., McGuirk, J. M., & Cornell, E. A. (2002) · Physical Review A · doi:10.1103/physreva.66.053616 · Cited by 231
General relativistic effects in atom interferometry
Dimopoulos, S., Graham, P. W., Hogan, J. M., & Kasevich, M. A. (2008) · Physical Review D · doi:10.1103/physrevd.78.042003 · Cited by 200
In-orbit operation of an atomic clock based on laser-cooled 87Rb atoms
Liu, L., Lü, D.-S., Chen, W.-B., Li, T., Qu, Q.-Z., Wang, B., Li, L., Ren, W., Dong, Z.-R., Zhao, J.-B., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-05219-z · Cited by 189
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Accuracy evaluation of an optical lattice clock with bosonic atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Le Coq, Y., Rovera, G. D., Bize, S., & Lemonde, P. (2007) · Optics Letters · doi:10.1364/ol.32.001812 · Cited by 100
Self-citationArias, E. F. (2005) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2005.1633 · Cited by 35
“The Bureau National de Métrologie (BNM, France) has developed a dual Cs–Rb fountain for which results have already been published (Sortais et al. 2000; Bize et al. 2004).”
Background
Metadata
- Authors
- Sortais, Y., Bize, S., Nicolas, C., Clairon, A., Salomon, C., & Williams, C.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2000-10-09
- Volume
- 85
- Issue
- 15
- Pages
- 3117-3120
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2086020229
- Cited by
- 132
- References
- 0
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.