CoChat

A strontium lattice clock with 3 × 10−17inaccuracy and its frequency

Open access
Falke, Stephan, Lemke, Nathan, Grebing, Christian, Lipphardt, Burghard, Weyers, Stefan, Gerginov, Vladislav, Huntemann, Nils, Hagemann, Christian, Al-Masoudi, Ali, Häfner, Sebastian, Vogt, Stefan, Sterr, Uwe, Lisdat, Christian · 2014 · New Journal of Physics

The DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.

Abstract

We have measured the absolute frequency of the optical lattice clock based on 87 Sr at PTB with an uncertainty of using two caesium fountain clocks. This is close to the accuracy of todayʼs best realizations of the SI second. The absolute frequency of the 5 s 2 1 S 0 – 5s5p 3 P 0 transition in 87 Sr is .13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach , opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy or optical clock evaluation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/1367-2630/16/7/073023

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 63 references

Research works printed but not linked: 3

  1. BIPM, 2008, JCGM 100:2008. Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement
  2. Weyers S, 2001, Proc. 6th Symp. on Frequency Standards and Metrology 2001, 64
  3. Yamaguchi A, 2012, Appl. Phys. Express, 5

Cited by

See all 182

Metadata

Authors
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., Vogt, S., Sterr, U., & Lisdat, C.
Affiliations
Physikalisch-Technische Bundesanstalt (DE)
Corresponding author
  • Grebing, Christian
  • Hagemann, Christian
  • Lisdat, Christian
Venue
New Journal of Physics
Published
2014-07-17
Volume
16
Issue
7
Pages
073023
ISSN
1367-2630 (ISSN-L)
OpenAlex
W1969928411
Cited by
182
References
63
Citations by year
2026: 2 · 2025: 4 · 2024: 10 · 2023: 15 · 2022: 14 · 2021: 7 · 2020: 11 · 2019: 14 · 2018: 20 · 2017: 16 · 2016: 29 · 2015: 29 · 2014: 10
FWCI
13.88
Type
journal article
Language
en
Open access
Licence
Locations
  • New Journal of Physics (publishedVersion, cc-by)
  • arXiv (Cornell University) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • arXiv (Cornell University)
Funders
  • Pennsylvania State University
  • European Association of National Metrology Institutes
  • Deutsche Forschungsgemeinschaft (RTG 1729)
  • Leibniz-Gemeinschaft
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
  • Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
Keywords
87Sr, optical lattice clock, absolute frequency measurement, frequency standards, systematic uncertainties, SI second, frequency ratio measurement, optical clocks

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A strontium lattice clock with 3 × 10−17inaccuracy and its frequency. https://app.cochat.ai/papers/10.1088/1367-2630/16/7/073023
The paper
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., Vogt, S., Sterr, U., & Lisdat, C. (2014). A strontium lattice clock with 3 × 10−17inaccuracy and its frequency. New Journal of Physics. https://doi.org/10.1088/1367-2630/16/7/073023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.