The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Experimental Demonstration of a Squeezing-Enhanced Power-Recycled Michelson Interferometer for Gravitational Wave Detection
Open accessAbstract
Interferometric gravitational wave detectors are expected to be limited by shot noise at some frequencies. We experimentally demonstrate that a power recycled Michelson with squeezed light injected into the dark port can overcome this limit. An improvement in the signal-to-noise ratio of 2.3 dB is measured and locked stably for long periods of time. The configuration, control, and signal readout of our experiment are compatible with current gravitational wave detector designs. We consider the application of our system to long baseline interferometer designs such as LIGO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum-mechanical noise in an interferometer
Caves, C. M. (1981) · Physical Review D · doi:10.1103/physrevd.23.1693 · Cited by 3,202
Cited by
A gravitational wave observatory operating beyond the quantum shot-noise limit
The LIGO Scientific Collaboration, Abadie, J., Abbott, B. P., Abbott, R., Abbott, T. D., Abernathy, M., Adams, C., Adhikari, R., Affeldt, C., Allen, B., et al. (2011) · Nature Physics · doi:10.1038/nphys2083 · Cited by 921
Self-citationSqueezed states of light and their applications in laser interferometers
Schnabel, R. (2017) · Physics Reports · doi:10.1016/j.physrep.2017.04.001 · Cited by 513
Observation of Squeezed Light with 10-dB Quantum-Noise Reduction
Vahlbruch, H., Mehmet, M., Chelkowski, S., Hage, B., Franzen, A., Lastzka, N., Goßler, S., Danzmann, K., & Schnabel, R. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.033602 · Cited by 473
First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory
Grote, H., Danzmann, K., Dooley, K. L., Schnabel, R., Slutsky, J., & Vahlbruch, H. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.181101 · Cited by 379
Fiber Optical Parametric Amplifiers, Oscillators and Related Devices
Marhic, M. E. (2007) · Cambridge University Press eBooks · doi:10.1017/cbo9780511600265 · Cited by 360
Metadata
- Authors
- McKenzie, K., Shaddock, D. A., McClelland, D. E., Buchler, B. C., & Lam, P. K.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2002-05-23
- Volume
- 88
- Issue
- 23
- Pages
- 231102-231102
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2054864165
- Cited by
- 220
- References
- 1
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental Demonstration of a Squeezing-Enhanced Power-Recycled Michelson Interferometer for Gravitational Wave Detection. https://app.cochat.ai/papers/10.1103/physrevlett.88.231102
- The paper
- McKenzie, K., Shaddock, D. A., McClelland, D. E., Buchler, B. C., & Lam, P. K. (2002). Experimental Demonstration of a Squeezing-Enhanced Power-Recycled Michelson Interferometer for Gravitational Wave Detection. Physical Review Letters. https://doi.org/10.1103/physrevlett.88.231102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.