The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Testing the Stability of Fundamental Constants with theHg+199Single-Ion Optical Clock
Open accessAbstract
Over a two-year duration, we have compared the frequency of the $^{199}\mathrm{H}\mathrm{g}^{+}$ $5{d}^{10}6s\text{ }^{2}S_{1/2}(F=0)\ensuremath{\leftrightarrow}5{d}^{9}6{s}^{2}\text{ }^{2}D_{5/2}(F=2)$ electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral $^{133}\mathrm{C}\mathrm{s}$. These measurements show that any fractional time variation of the ratio ${\ensuremath{\nu}}_{\mathrm{C}\mathrm{s}}/{\ensuremath{\nu}}_{\mathrm{H}\mathrm{g}}$ between the two frequencies is smaller than $\ifmmode\pm\else\textpm\fi{}7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}\text{ }{\mathrm{y}\mathrm{r}}^{\ensuremath{-}1}$ ($1\ensuremath{\sigma}$ uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of ${g}_{\mathrm{C}\mathrm{s}}({m}_{e}/{m}_{p}){\ensuremath{\alpha}}^{6.0}$ at the same level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Self-citationQuantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Self-citationThe Oklo bound on the time variation of the fine-structure constant revisited
Damour, T., & Dyson, F. (1996) · Nuclear Physics B · doi:10.1016/s0550-3213(96)00467-1 · Cited by 374
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Self-citationDirect test of the constancy of fundamental nuclear constants
SHLYAKHTER, A. I. (1976) · Nature · doi:10.1038/264340a0 · Cited by 269
Cited by
The Confrontation between General Relativity and Experiment
Will, C. M. (2014) · Living Reviews in Relativity · doi:10.12942/lrr-2014-4 · Cited by 3,996
Theory and Experiment in Gravitational Physics
Will, C. M. (2018) · doi:10.1017/9781316338612 · Cited by 3,637
The Confrontation between General Relativity and Experiment
Will, C. M. (2006) · Living Reviews in Relativity · doi:10.12942/lrr-2006-3 · Cited by 1,606
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Metadata
- Authors
- Bize, S., Diddams, S. A., Tanaka, U., Tanner, C. E., Oskay, W. H., Drullinger, R. E., Parker, T. E., Heavner, T. P., Jefferts, S. R., Hollberg, L., Itano, W. M., & Bergquist, J. C.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2003-04-18
- Volume
- 90
- Issue
- 15
- Pages
- 150802-150802
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2096509967
- Cited by
- 249
- References
- 5
- FWCI
- 19.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Testing the Stability of Fundamental Constants with theHg+199Single-Ion Optical Clock. https://app.cochat.ai/papers/10.1103/physrevlett.90.150802
- The paper
- Bize, S., Diddams, S. A., Tanaka, U., Tanner, C. E., Oskay, W. H., Drullinger, R. E., Parker, T. E., Heavner, T. P., Jefferts, S. R., Hollberg, L., Itano, W. M., & Bergquist, J. C. (2003). Testing the Stability of Fundamental Constants with theHg+199Single-Ion Optical Clock. Physical Review Letters. https://doi.org/10.1103/physrevlett.90.150802
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.