The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Testing the Stability of Fundamental Constants with theHg+199Single-Ion Optical Clock
Open accessAbstract
Over a two-year duration, we have compared the frequency of the $^{199}\mathrm{H}\mathrm{g}^{+}$ $5{d}^{10}6s\text{ }^{2}S_{1/2}(F=0)\ensuremath{\leftrightarrow}5{d}^{9}6{s}^{2}\text{ }^{2}D_{5/2}(F=2)$ electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral $^{133}\mathrm{C}\mathrm{s}$. These measurements show that any fractional time variation of the ratio ${\ensuremath{\nu}}_{\mathrm{C}\mathrm{s}}/{\ensuremath{\nu}}_{\mathrm{H}\mathrm{g}}$ between the two frequencies is smaller than $\ifmmode\pm\else\textpm\fi{}7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}\text{ }{\mathrm{y}\mathrm{r}}^{\ensuremath{-}1}$ ($1\ensuremath{\sigma}$ uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of ${g}_{\mathrm{C}\mathrm{s}}({m}_{e}/{m}_{p}){\ensuremath{\alpha}}^{6.0}$ at the same level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Further Evidence for Cosmological Evolution of the Fine Structure Constant
Webb, J. K., Murphy, M. T., Flambaum, V. V., Dzuba, V. A., Barrow, J. D., Churchill, C. W., Prochaska, J. X., & Wolfe, A. M. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.091301 · Cited by 824
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Self-citationQuantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Self-citationThe Oklo bound on the time variation of the fine-structure constant revisited
Damour, T., & Dyson, F. (1996) · Nuclear Physics B · doi:10.1016/s0550-3213(96)00467-1 · Cited by 374
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Self-citationDirect test of the constancy of fundamental nuclear constants
SHLYAKHTER, A. I. (1976) · Nature · doi:10.1038/264340a0 · Cited by 269
Cited by
The Confrontation between General Relativity and Experiment
Will, C. M. (2014) · Living Reviews in Relativity · doi:10.12942/lrr-2014-4 · Cited by 3,996
Theory and Experiment in Gravitational Physics
Will, C. M. (2018) · doi:10.1017/9781316338612 · Cited by 3,637
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
The Confrontation between General Relativity and Experiment
Will, C. M. (2006) · Living Reviews in Relativity · doi:10.12942/lrr-2006-3 · Cited by 1,606
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Nobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Varying Constants, Gravitation and Cosmology
Uzan, J.-P. (2011) · Living Reviews in Relativity · doi:10.12942/lrr-2011-2 · Cited by 740
Optical frequency combs: Coherently uniting the electromagnetic spectrum
Diddams, S. A., Vahala, K., & Udem, T. (2020) · Science · doi:10.1126/science.aay3676 · Cited by 714
Self-citationCODATA recommended values of the fundamental physical constants: 2002
Mohr, P. J., & Taylor, B. N. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.1 · Cited by 654
New Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Self-citationRemote transfer of ultrastable frequency references via fiber networks
Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007) · Review of Scientific Instruments · doi:10.1063/1.2437069 · Cited by 403
Wynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
Optical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319
Self-citationDi Valentino, E., Said, J. L., Riess, A., Pollo, A., Poulin, V., Gómez-Valent, A., Weltman, A., Palmese, A., Huang, C. D., Bruck, C. V. D., et al. (2025) · Physics of the Dark Universe · doi:10.1016/j.dark.2025.101965 · Cited by 319
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Self-citationSingle-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297
Self-citationLimit on the Present Temporal Variation of the Fine Structure Constant
Peik, E., Lipphardt, B., Schnatz, H., Schneider, T., Tamm, C., & Karshenboim, S. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.170801 · Cited by 282
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Standards of Time and Frequency at the Outset of the 21st Century
Diddams, S. A., Bergquist, J. C., Jefferts, S. R., & Oates, C. W. (2004) · Science · doi:10.1126/science.1102330 · Cited by 275
Self-citationFlambaum, V. V. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.092502 · Cited by 254
Fortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Self-citationFlambaum, V. V., & Tedesco, A. F. (2006) · Physical Review C · doi:10.1103/physrevc.73.055501 · Cited by 163
Planck intermediate results: XXIV. Constraints on variations in fundamental constants⋆
Planck Collaboration:, Ade, P. A. R., Aghanim, N., Arnaud, M., Ashdown, M., Aumont, J., Baccigalupi, C., Banday, A. J., Barreiro, R. B., Battaner, E., et al. (2015) · Astronomy & Astrophysics · doi:10.1051/0004-6361/201424496 · Cited by 125
New constraints on time-dependent variations of fundamental constants using Planck data
Hart, L., & Chluba, J. (2018) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/stx2783 · Cited by 96
“This is ' 2−3 orders of magnitude weaker than constraints obtained from ‘local’ measurements (Bize et al. 2003; Rosenband et al. 2008; Bonifacio et al. 2014; Kotuš et al. 2017); however, the CMB places limits during very different phases in the c© 2017 RAS ar X iv :1 70 5.”
Limit on the Temporal Variation of the Fine-Structure Constant Using Atomic Dysprosium
Cingöz, A., Lapierre, A., Nguyen, A.-T., Leefer, N., Budker, D., Lamoreaux, S. K., & Torgerson, J. R. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.040801 · Cited by 88
Sensitivity of hyperfine structure to nuclear radius and quark mass variation
Dinh, T. H., Dunning, A., Dzuba, V. A., & Flambaum, V. V. (2009) · Physical Review A · doi:10.1103/physreva.79.054102 · Cited by 46
String Theory, Gravity and Experiment
Damour, T., & Lilley, M. (2008) · Les Houches · doi:10.1016/s0924-8099(08)80027-3 · Cited by 35
Gyromagnetic factors and atomic clock constraints on the variation of fundamental constants
Luo, F., Olive, K. A., & Uzan, J.-P. (2011) · Physical Review D · doi:10.1103/physrevd.84.096004 · Cited by 31
Fundamental constants: from measurement to the universe, a window on gravitation and cosmology
Uzan, J.-P. (2025) · Living Reviews in Relativity · doi:10.1007/s41114-025-00059-y · Cited by 36
Hart, L., & Chluba, J. (2023) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/stac3697 · Cited by 28
Metadata
- Authors
- Bize, S., Diddams, S. A., Tanaka, U., Tanner, C. E., Oskay, W. H., Drullinger, R. E., Parker, T. E., Heavner, T. P., Jefferts, S. R., Hollberg, L., Itano, W. M., & Bergquist, J. C.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2003-04-18
- Volume
- 90
- Issue
- 15
- Pages
- 150802-150802
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2096509967
- Cited by
- 249
- References
- 6
- FWCI
- 19.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.