The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Six-Axis Inertial Sensor Using Cold-Atom Interferometry
Open accessAbstract
We have developed an atom interferometer providing a full inertial base. This device uses two counterpropagating cold-atom clouds that are launched in strongly curved parabolic trajectories. Three single Raman beam pairs, pulsed in time, are successively applied in three orthogonal directions leading to the measurement of the three axis of rotation and acceleration. In this purpose, we introduce a new atom gyroscope using a butterfly geometry. We discuss the present sensitivity and the possible improvements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic interferometry using stimulated Raman transitions
Kasevich, M., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.181 · Cited by 1,377
High-precision gravity measurements using atom interferometry
Peters, A., Chung, K. Y., & Chu, S. (2001) · Metrologia · doi:10.1088/0026-1394/38/1/4 · Cited by 965
Precision Rotation Measurements with an Atom Interferometer Gyroscope
Gustavson, T. L., Bouyer, P., & Kasevich, M. A. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.2046 · Cited by 785
Self-citationYoung’s double-slit experiment with atoms: A simple atom interferometer
Carnal, O., & Mlynek, J. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.2689 · Cited by 626
Sensitive absolute-gravity gradiometry using atom interferometry
McGuirk, J. M., Foster, G. T., Fixler, J. B., Snadden, M. J., & Kasevich, M. A. (2002) · Physical Review A · doi:10.1103/physreva.65.033608 · Cited by 586
Keith, D. W., Ekstrom, C. R., Turchette, Q. A., & Pritchard, D. E. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.2693 · Cited by 582
Optical Ramsey spectroscopy in a rotating frame: Sagnac effect in a matter-wave interferometer
Riehle, F., Kisters, T., Witte, A., Helmcke, J., & Bordé, C. J. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.177 · Cited by 541
Self-citationAtomic interferometry with internal state labelling
Bordé, C. J. (1989) · Physics Letters A · doi:10.1016/0375-9601(89)90537-9 · Cited by 535
Self-citationRotation sensing with a dual atom-interferometer Sagnac gyroscope
Gustavson, T. L., Landragin, A., & Kasevich, M. A. (2000) · Classical and Quantum Gravity · doi:10.1088/0264-9381/17/12/311 · Cited by 470
Self-citationAtomic velocity selection using stimulated Raman transitions
Kasevich, M., Weiss, D. S., Riis, E., Moler, K., Kasapi, S., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.2297 · Cited by 305
Rotation Sensing with an Atom Interferometer
Lenef, A., Hammond, T. D., Smith, E. T., Chapman, M. S., Rubenstein, R. A., & Pritchard, D. E. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.760 · Cited by 197
A cesium fountain frequency standard: preliminary results
Clairon, A., Laurent, P., Santarelli, G., Ghezali, S., Lea, S. N., & Bahoura, M. (1995) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.377790 · Cited by 171
Self-citationBordé, C. (2004) · General Relativity and Gravitation · doi:10.1023/b:gerg.0000010726.64769.6d · Cited by 74
Self-citationInfluence of optical aberrations in an atomic gyroscope
Fils, J., Leduc, F., Bouyer, P., Holleville, D., Dimarcq, N., Clairon, A., & Landragin, A. (2005) · The European Physical Journal D · doi:10.1140/epjd/e2005-00255-9 · Cited by 38
Self-citation
Cited by
Matter-gravity couplings and Lorentz violation
Kostelecký, V. A., & Tasson, J. D. (2011) · Physical Review D · doi:10.1103/physrevd.83.016013 · Cited by 341
Kitching, J., Knappe, S., & Donley, E. A. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157679 · Cited by 330
Limits to the sensitivity of a low noise compact atomic gravimeter
Le Gouët, J., Mehlstäubler, T. E., Kim, J., Merlet, S., Clairon, A., Landragin, A., & Pereira Dos Santos, F. (2008) · Applied Physics B · doi:10.1007/s00340-008-3088-1 · Cited by 294
Self-citationExploring gravity with the MIGA large scale atom interferometer
Canuel, B., Bertoldi, A., Amand, L., Pozzo di Borgo, E., Chantrait, T., Danquigny, C., Dovale Álvarez, M., Fang, B., Freise, A., Geiger, R., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32165-z · Cited by 285
Self-citationContinuous Cold-Atom Inertial Sensor with1 nrad/secRotation Stability
Dutta, I., Savoie, D., Fang, B., Venon, B., Garrido Alzar, C. L., Geiger, R., & Landragin, A. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.183003 · Cited by 284
Self-citation
Metadata
- Authors
- Canuel, B., Leduc, F., Holleville, D., Gauguet, A., Fils, J., Virdis, A., Clairon, A., Dimarcq, N., Bordé, C. J., Landragin, A., & Bouyer, P.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2006-07-07
- Volume
- 97
- Issue
- 1
- Pages
- 010402-010402
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2052489544
- Cited by
- 387
- References
- 14
- FWCI
- 9.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.