The DOI matches its Crossref record.
A cesium fountain frequency standard: preliminary results
Abstract
An atomic frequency standard based on a fountain of cold cesium atoms has been in operation in our laboratory for a few months. Ramsey fringes as narrow as 0.7 Hz have been obtained. The short-term frequency stability, measured against an H-maser, is 3 10/sup -13/ /spl tau//sup -1/2/, probably limited by the local oscillator frequency noise. A preliminary evaluation of some systematic effects shows that cold collisions will be the limiting effect for long-term stability and accuracy. Measurements of this shift presented here, using a magnetooptical trap, show that at low density an uncertainty of about 10/sup 15/ is obtained. Under these conditions, the number of atoms is large enough to allow a potential stability of 10/sup -13/ /spl tau//sup -1/2/ to be reached. When optical molasses is used, the initial density is lower and collisional effects are reduced by a factor of three.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard
Santarelli, G., Laurent, P., Lemonde, P., Clairon, A., Mann, A. G., Chang, S., Luiten, A. N., & Salomon, C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4619 · Cited by 569
Self-citationLaser cooling and trapping of neutral atoms
Adams, C. S., & Riis, E. (1997) · Progress in Quantum Electronics · doi:10.1016/s0079-6727(96)00006-7 · Cited by 557
Six-Axis Inertial Sensor Using Cold-Atom Interferometry
Canuel, B., Leduc, F., Holleville, D., Gauguet, A., Fils, J., Virdis, A., Clairon, A., Dimarcq, N., Bordé, C. J., Landragin, A., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.010402 · Cited by 387
Self-citationKitching, J., Knappe, S., & Donley, E. A. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157679 · Cited by 330
Metadata
- Authors
- Clairon, A., Laurent, P., Santarelli, G., Ghezali, S., Lea, S. N., & Bahoura, M.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 1995-04
- Volume
- 44
- Issue
- 2
- Pages
- 128-131
- ISSN
- 0018-9456 (ISSN-L)
- OpenAlex
- W2163508343
- Cited by
- 171
- References
- 0
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A cesium fountain frequency standard: preliminary results. https://app.cochat.ai/papers/10.1109/19.377790
- The paper
- Clairon, A., Laurent, P., Santarelli, G., Ghezali, S., Lea, S. N., & Bahoura, M. (1995). A cesium fountain frequency standard: preliminary results. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/19.377790
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.