The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Concentration Polarization and Nonlinear Electrokinetic Flow near a Nanofluidic Channel
Open accessAbstract
A perm-selective nanochannel could initiate concentration polarization near the nanochannel, significantly decreasing (increasing) the ion concentration in the anodic (cathodic) end of the nanochannel. Such strong concentration polarization can be induced even at moderate buffer concentrations because of local ion depletion (therefore thicker local Debye layer) near the nanochannel. In addition, fast fluid vortices were generated at the anodic side of the nanochannel due to the nonequilibrium electro-osmotic flow (EOF), which was at least approximately 10x faster than predicted from any equilibrium EOF. This result corroborates the relation among induced EOF, concentration polarization, and limiting-current behavior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface-Charge-Governed Ion Transport in Nanofluidic Channels
Stein, D., Kruithof, M., & Dekker, C. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.035901 · Cited by 1,162
Separation of Long DNA Molecules in a Microfabricated Entropic Trap Array
Han, J., & Craighead, H. G. (2000) · Science · doi:10.1126/science.288.5468.1026 · Cited by 924
Self-citationPhysicochemical hydrodynamics: an introduction
(1995) · Choice Reviews Online · doi:10.5860/choice.32-3319 · Cited by 878
Induced-charge electro-osmosis
SQUIRES, T. M., & BAZANT, M. Z. (2004) · Journal of Fluid Mechanics · doi:10.1017/s0022112004009309 · Cited by 716
Million-fold Preconcentration of Proteins and Peptides by Nanofluidic Filter
Wang, Y.-C., Stevens, A. L., & Han, J. (2005) · Analytical Chemistry · doi:10.1021/ac050321z · Cited by 618
Self-citationElectro-osmotically induced convection at a permselective membrane
Rubinstein, I., & Zaltzman, B. (2000) · Physical Review E · doi:10.1103/physreve.62.2238 · Cited by 615
Ion-Enrichment and Ion-Depletion Effect of Nanochannel Structures
Pu, Q., Yun, J., Temkin, H., & Liu, S. (2004) · Nano Letters · doi:10.1021/nl0494811 · Cited by 532
Voltage against current curves of cation exchange membranes
Rubinstein, I., & Shtilman, L. (1979) · Journal of the Chemical Society, Faraday Transactions 2 · doi:10.1039/f29797500231 · Cited by 442
Electro-osmotic slip and electroconvective instability
ZALTZMAN, B., & RUBINSTEIN, I. (2007) · Journal of Fluid Mechanics · doi:10.1017/s0022112007004880 · Cited by 416
Plecis, A., Schoch, R. B., & Renaud, P. (2005) · Nano Letters · doi:10.1021/nl050265h · Cited by 384
Cited by
Transport phenomena in nanofluidics
Schoch, R. B., Han, J., & Renaud, P. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.839 · Cited by 1,933
Self-citationStrategies for the Stabilization of Zn Metal Anodes for Zn‐Ion Batteries
Yi, Z., Chen, G., Hou, F., Wang, L., & Liang, J. (2021) · Advanced Energy Materials · doi:10.1002/aenm.202003065 · Cited by 942
Bazant, M. Z., Kilic, M. S., Storey, B. D., & Ajdari, A. (2009) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2009.10.001 · Cited by 916
Direct seawater desalination by ion concentration polarization
Kim, S. J., Ko, S. H., Kang, K. H., & Han, J. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.34 · Cited by 783
Self-citationElectrochemical Methods for Water Purification, Ion Separations, and Energy Conversion
Alkhadra, M. A., Su, X., Suss, M. E., Tian, H., Guyes, E. N., Shocron, A. N., Conforti, K. M., de Souza, J. P., Kim, N., Tedesco, M., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00396 · Cited by 661
Ion Concentration Polarization by Bifurcated Current Path
Kim, J., Cho, I., Lee, H., & Kim, S. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-04646-0 · Cited by 644
Self-citationIonic Selectivity of Single Nanochannels
Vlassiouk, I., Smirnov, S., & Siwy, Z. (2008) · Nano Letters · doi:10.1021/nl800949k · Cited by 456
Desalination at overlimiting currents: State-of-the-art and perspectives
Nikonenko, V. V., Kovalenko, A. V., Urtenov, M. K., Pismenskaya, N. D., Han, J., Sistat, P., & Pourcelly, G. (2014) · Desalination · doi:10.1016/j.desal.2014.01.008 · Cited by 405
Self-citationKim, S. J., Song, Y.-A., & Han, J. (2010) · Chemical Society Reviews · doi:10.1039/b822556g · Cited by 405
Self-citationAnomalous ion transport in 2-nm hydrophilic nanochannels
Duan, C., & Majumdar, A. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.233 · Cited by 404
Nikonenko, V. V., Pismenskaya, N. D., Belova, E. I., Sistat, P., Huguet, P., Pourcelly, G., & Larchet, C. (2010) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.08.001 · Cited by 380
Critical Knowledge Gaps in Mass Transport through Single-Digit Nanopores: A Review and Perspective
Faucher, S., Aluru, N., Bazant, M. Z., Blankschtein, D., Brozena, A. H., Cumings, J., Pedro de Souza, J., Elimelech, M., Epsztein, R., Fourkas, J. T., et al. (2019) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.9b02178 · Cited by 365
Self-citationNanofluidics in two-dimensional layered materials: inspirations from nature
Gao, J., Feng, Y., Guo, W., & Jiang, L. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00369b · Cited by 321
Molecular sieving using nanofilters: Past, present and future
Han, J., Fu, J., & Schoch, R. B. (2008) · Lab Chip · doi:10.1039/b714128a · Cited by 293
Self-citationReview article: Fabrication of nanofluidic devices
Duan, C., Wang, W., & Xie, Q. (2013) · Biomicrofluidics · doi:10.1063/1.4794973 · Cited by 274
Micro/nano acoustofluidics: materials, phenomena, design, devices, and applications
Connacher, W., Zhang, N., Huang, A., Mei, J., Zhang, S., Gopesh, T., & Friend, J. (2018) · Lab on a Chip · doi:10.1039/c8lc00112j · Cited by 269
Advancements in microfluidics for nanoparticle separation
Salafi, T., Zeming, K. K., & Zhang, Y. (2017) · Lab on a Chip · doi:10.1039/c6lc01045h · Cited by 261
Metadata
- Authors
- Kim, S. J., Wang, Y.-C., Lee, J. H., Jang, H., & Han, J.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2007-07-25
- Volume
- 99
- Issue
- 4
- Pages
- 044501-044501
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2137564178
- Cited by
- 555
- References
- 12
- FWCI
- 16.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.