The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Attosecond Control of Ionization by Wave-Packet Interference
Open accessAbstract
A train of attosecond pulses, synchronized to an infrared (IR) laser field, is used to create a series of electron wave packets (EWPs) that are below the ionization threshold in .helium. The ionization probability is found to strongly oscillate with the delay between the IR and attosecond fields twice per IR laser cycle. Calculations that reproduce the experimental results demonstrate that this ionization control results from interference between transiently bound EWPs created by different pulses in the train. In this way, we are able to observe, for the first time, attosecond wave-packet interference in a strongly driven atomic system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Observation of a Train of Attosecond Pulses from High Harmonic Generation
Paul, P. M., Toma, E. S., Breger, P., Mullot, G., Augé, F., Balcou, P., Muller, H. G., & Agostini, P. (2001) · Science · doi:10.1126/science.1059413 · Cited by 2,801
Time-resolved atomic inner-shell spectroscopy
Drescher, M., Hentschel, M., Kienberger, R., Uiberacker, M., Yakovlev, V., Scrinzi, A., Westerwalbesloh, T., Kleineberg, U., Heinzmann, U., & Krausz, F. (2002) · Nature · doi:10.1038/nature01143 · Cited by 1,470 · cited 1×
“Previous attosecond experiments have used the UV pulse to control the time at which an ionization process takes place [3, 4, 5, 6, 7, 13].”
Cited by
Attosecond metrology: from electron capture to future signal processing
Krausz, F., & Stockman, M. I. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.28 · Cited by 501
Kling, M. F., & Vrakking, M. J. J. (2008) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.59.032607.093532 · Cited by 334
Coherent control with a short-wavelength free-electron laser
Prince, K. C., Allaria, E., Callegari, C., Cucini, R., De Ninno, G., Di Mitri, S., Diviacco, B., Ferrari, E., Finetti, P., Gauthier, D., et al. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.13 · Cited by 240
Real-Time Probing of Electron Dynamics Using Attosecond Time-Resolved Spectroscopy
Ramasesha, K., Leone, S. R., & Neumark, D. M. (2016) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040215-112025 · Cited by 225
Loh, Z.-H., & Leone, S. R. (2013) · The Journal of Physical Chemistry Letters · doi:10.1021/jz301910n · Cited by 66
Metadata
- Authors
- Johnsson, P., Mauritsson, J., Remetter, T., L’Huillier, A., & Schafer, K. J.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2007-12-07
- Volume
- 99
- Issue
- 23
- Pages
- 233001-233001
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2125117395
- Cited by
- 182
- References
- 2
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.