The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Magnetic resonance force microscopy
Abstract
Recent initial experiments in magnetic resonance force microscopy (MRFM) have detected the magnetic force exerted by electrons and nuclei in microscopic samples. The experiments generate a force signal by modulating the sample magnetization with standard magnetic resonance techniques. Sample sizes of a few nanograms generate readily detected force signals of order ${10}^{\ensuremath{-}14}$ to ${10}^{\ensuremath{-}16}$ Newtons. This article describes the present status of MRFM technology, with particular attention to the feasibility of detecting single-electron magnetic moments, and the possible applications of MRFM in biological imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A single quantum cannot be cloned
Wootters, W. K., & Zurek, W. H. (1982) · Nature · doi:10.1038/299802a0 · Cited by 5,406
Quantum-mechanical noise in an interferometer
Caves, C. M. (1981) · Physical Review D · doi:10.1103/physrevd.23.1693 · Cited by 3,202
Crystal Structure of a p53 Tumor Suppressor-DNA Complex: Understanding Tumorigenic Mutations
Cho, Y., Gorina, S., Jeffrey, P. D., & Pavletich, N. P. (1994) · Science · doi:10.1126/science.8023157 · Cited by 2,551
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
Experiments with an isolated subatomic particle at rest
Dehmelt, H. (1990) · Reviews of Modern Physics · doi:10.1103/revmodphys.62.525 · Cited by 302
Cited by
DiVincenzo, D. P. (1995) · Science · doi:10.1126/science.270.5234.255 · Cited by 1,651
A tunable carbon nanotube electromechanical oscillator
Sazonova, V., Yaish, Y., Üstünel, H., Roundy, D., Arias, T. A., & McEuen, P. L. (2004) · Nature · doi:10.1038/nature02905 · Cited by 1,312
High-Resolution Microcoil 1 H-NMR for Mass-Limited, Nanoliter-Volume Samples
Olson, D. L., Peck, T. L., Webb, A. G., Magin, R. L., & Sweedler, J. V. (1995) · Science · doi:10.1126/science.270.5244.1967 · Cited by 503
Metadata
- Authors
- Sidles, J. A., Garbini, J. L., Bruland, K. J., Rugar, D., Züger, O., Hoen, S., & Yannoni, C. S.
- Venue
- Reviews of Modern Physics
- Publisher
- American Physical Society (APS)
- Published
- 1995-01-01
- Volume
- 67
- Issue
- 1
- Pages
- 249-265
- ISSN
- 0034-6861 (ISSN-L)
- 1539-0756
- OpenAlex
- W3150756696
- Cited by
- 466
- References
- 5
- FWCI
- 8.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic resonance force microscopy. https://app.cochat.ai/papers/10.1103/revmodphys.67.249
- The paper
- Sidles, J. A., Garbini, J. L., Bruland, K. J., Rugar, D., Züger, O., Hoen, S., & Yannoni, C. S. (1995). Magnetic resonance force microscopy. Reviews of Modern Physics. https://doi.org/10.1103/revmodphys.67.249
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.