Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 399

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The Mechanical Behavior of Vascular Grafts: A Review

Salacinski, Henryk J., Goldner, Sean, Giudiceandrea, Alberto, Hamilton, George, Seifalian, Alexander M., Edwards, Alan, Carson, Robert J.·2001·Journal of Biomaterials Applications

Abstract

The development of intimal hyperplasia (IH) near the anastomosis of a vascular graft to artery is directly related to changes in the wall shear rate distribution. Mismatch in compliance and diameter at the end-to-end anastomosis of a compliant artery and rigid graft cause shear rate disturbances that may induce intimal hyperplasia and ultimately graft failure. The principal strategy being developed to prevent IH is based on the design and fabrication of compliant synthetic or innovative tissue-engineered grafts with viscoelastic properties that mirror those of the human artery. The goal of this review is to discuss how mechanical properties including compliance mismatch, diameter mismatch, Young’s modulus and impedance phase angle affect graft failure due to intimal hyperplasia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1106/na5t-j57a-jtdd-fd04

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Mechanical Properties of Arteries in Vivo

    PETERSON, L. H., JENSEN, R. E., & PARNELL, J. (1960) · Circulation Research · doi:10.1161/01.res.8.3.622 · Cited by 679 · cited 1×

    “However, this methodology is highly invasive, imposing a mechanical restraint on the vessel with the need to apply calipers or coils, so it can only be used intra-operatively [67].”

Show all 1 references

Cited by

See all 399

Metadata

Authors
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J.
Venue
Journal of Biomaterials Applications
Published
2001-01
Volume
15
Issue
3
Pages
241-278
ISSN
  • 0885-3282 (ISSN-L)
  • 1530-8022
OpenAlex
W2148852502
Cited by
399
References
1
FWCI
10.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Mechanical Behavior of Vascular Grafts: A Review. https://app.cochat.ai/papers/10.1106/na5t-j57a-jtdd-fd04
The paper
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001). The Mechanical Behavior of Vascular Grafts: A Review. Journal of Biomaterials Applications. https://doi.org/10.1106/na5t-j57a-jtdd-fd04

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.