The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Mechanical Behavior of Vascular Grafts: A Review
Abstract
The development of intimal hyperplasia (IH) near the anastomosis of a vascular graft to artery is directly related to changes in the wall shear rate distribution. Mismatch in compliance and diameter at the end-to-end anastomosis of a compliant artery and rigid graft cause shear rate disturbances that may induce intimal hyperplasia and ultimately graft failure. The principal strategy being developed to prevent IH is based on the design and fabrication of compliant synthetic or innovative tissue-engineered grafts with viscoelastic properties that mirror those of the human artery. The goal of this review is to discuss how mechanical properties including compliance mismatch, diameter mismatch, Young’s modulus and impedance phase angle affect graft failure due to intimal hyperplasia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanical Properties of Arteries in Vivo
PETERSON, L. H., JENSEN, R. E., & PARNELL, J. (1960) · Circulation Research · doi:10.1161/01.res.8.3.622 · Cited by 679 · cited 1×
“However, this methodology is highly invasive, imposing a mechanical restraint on the vessel with the need to apply calipers or coils, so it can only be used intra-operatively [67].”
Cited by
B IOFLUID M ECHANICS IN F LEXIBLE T UBES
Grotberg, J. B., & Jensen, O. E. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121918 · Cited by 455
Rapid continuous 3D printing of customizable peripheral nerve guidance conduits
Zhu, W., Tringale, K. R., Woller, S. A., You, S., Johnson, S., Shen, H., Schimelman, J., Whitney, M., Steinauer, J., Xu, W., et al. (2018) · Materials Today · doi:10.1016/j.mattod.2018.04.001 · Cited by 253
Cheng, J., Wang, C., & Gu, Y. (2019) · Bio-Medical Materials and Engineering · doi:10.3233/bme-191044 · Cited by 45
Metadata
- Authors
- Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J.
- Venue
- Journal of Biomaterials Applications
- Publisher
- SAGE Publications
- Published
- 2001-01
- Volume
- 15
- Issue
- 3
- Pages
- 241-278
- ISSN
- 0885-3282 (ISSN-L)
- 1530-8022
- OpenAlex
- W2148852502
- Cited by
- 399
- References
- 1
- FWCI
- 10.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Mechanical Behavior of Vascular Grafts: A Review. https://app.cochat.ai/papers/10.1106/na5t-j57a-jtdd-fd04
- The paper
- Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001). The Mechanical Behavior of Vascular Grafts: A Review. Journal of Biomaterials Applications. https://doi.org/10.1106/na5t-j57a-jtdd-fd04
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.