The Mechanical Behavior of Vascular Grafts: A Review
The DOI matches its Crossref record; 101 of the 101 references it cites were found in a registry or an index.
Abstract
The development of intimal hyperplasia (IH) near the anastomosis of a vascular graft to artery is directly related to changes in the wall shear rate distribution. Mismatch in compliance and diameter at the end-to-end anastomosis of a compliant artery and rigid graft cause shear rate disturbances that may induce intimal hyperplasia and ultimately graft failure. The principal strategy being developed to prevent IH is based on the design and fabrication of compliant synthetic or innovative tissue-engineered grafts with viscoelastic properties that mirror those of the human artery. The goal of this review is to discuss how mechanical properties including compliance mismatch, diameter mismatch, Young’s modulus and impedance phase angle affect graft failure due to intimal hyperplasia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The pathogenesis of atherosclerosis: a perspective for the 1990s
Ross, R. (1993) · Nature · doi:10.1038/362801a0 · Cited by 10,630
Risau, W. (1997) · Nature · doi:10.1038/386671a0 · Cited by 5,727 · cited 1×
“This process involves a complex set of interactions between SMC, endothelial cells (EC) and a number of growth factors and cytokines deriving from a disruption in the balance between inhibitory and stimulating factors at circa three months, as steady state is reached, with matrix predominating in the initially SMC-ric…”
BackgroundBiomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
A completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
Caro, C. G., Fitz-Gerald, J. M., & Schroter, R. C. (1971) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1971.0019 · Cited by 1,357
Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients
FRY, D. L. (1968) · Circulation Research · doi:10.1161/01.res.22.2.165 · Cited by 1,238
Flow Effects on Prostacyclin Production by Cultured Human Endothelial Cells
Frangos, J. A., Eskin, S. G., McIntire, L. V., & Ives, C. L. (1985) · Science · doi:10.1126/science.3883488 · Cited by 1,235
Veith, F. J., Gupta, S. K., Ascer, E., White-Flores, S., Samson, R. H., Scher, L. A., Towne, J. B., Bernhard, V. M., Bonier, P., Flinn, W. R., et al. (1986) · Journal of Vascular Surgery · doi:10.1016/0741-5214(86)90073-x · Cited by 1,112
Cited by
Current advances in research and clinical applications of PLGA-based nanotechnology
Lü, J.-M., Wang, X., Marin-Muller, C., Wang, H., Lin, P. H., Yao, Q., & Chen, C. (2009) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.09.15 · Cited by 903
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Current status of prosthetic bypass grafts: A review
Kannan, R. Y., Salacinski, H. J., Butler, P. E., Hamilton, G., & Seifalian, A. M. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30247 · Cited by 527
Self-citationBiomaterials in the development and future of vascular grafts
Xue, L., & Greisler, H. P. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.88 · Cited by 519
He, W., Ma, Z., Yong, T., Teo, W. E., & Ramakrishna, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.049 · Cited by 468
B IOFLUID M ECHANICS IN F LEXIBLE T UBES
Grotberg, J. B., & Jensen, O. E. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121918 · Cited by 455
Wang, Z., Cui, Y., Wang, J., Yang, X., Wu, Y., Wang, K., Gao, X., Li, D., Li, Y., Zheng, X.-L., et al. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.078 · Cited by 435
Kannan, R. Y., Salacinski, H. J., Sales, K., Butler, P., & Seifalian, A. M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.006 · Cited by 373
Self-citationHe, W., Yong, T., Teo, W. E., Ma, Z., & Ramakrishna, S. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.1574 · Cited by 370
Camasão, D. B., & Mantovani, D. (2021) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100106 · Cited by 310
Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review
Haruguchi, H., & Teraoka, S. (2003) · Journal of Artificial Organs · doi:10.1007/s10047-003-0232-x · Cited by 303
The Mechanical Properties of Infrainguinal Vascular Bypass Grafts: Their Role in Influencing Patency
Sarkar, S., Salacinski, H. J., Hamilton, G., & Seifalian, A. M. (2006) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2006.01.006 · Cited by 301
Self-citationMeinel, A. J., Germershaus, O., Luhmann, T., Merkle, H. P., & Meinel, L. (2012) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2012.01.016 · Cited by 270
Puskas, J. E., & Chen, Y. (2004) · Biomacromolecules · doi:10.1021/bm034513k · Cited by 269
Rapid continuous 3D printing of customizable peripheral nerve guidance conduits
Zhu, W., Tringale, K. R., Woller, S. A., You, S., Johnson, S., Shen, H., Schimelman, J., Whitney, M., Steinauer, J., Xu, W., et al. (2018) · Materials Today · doi:10.1016/j.mattod.2018.04.001 · Cited by 253
Brinkman, W. T., Nagapudi, K., Thomas, B. S., & Chaikof, E. L. (2003) · Biomacromolecules · doi:10.1021/bm0257412 · Cited by 246
Dalton, P. D., Flynn, L., & Shoichet, M. S. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00120-5 · Cited by 239
“Despite a wealth of knowledge on compliance mismatch resulting in failure of other implants, such as vascular grafts and bone [20–22], previously used nerve guidance channels, with the exception of collagen, are considerably more rigid than soft spinal cord tissue.”
BackgroundLee, S. J., Oh, S. H., Liu, J., Soker, S., Atala, A., & Yoo, J. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.11.024 · Cited by 226
Seifalian, A. M., Tiwari, A., Hamilton, G., & Salacinski, H. J. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06841.x · Cited by 225
Self-citationBodin, A., Ahrenstedt, L., Fink, H., Brumer, H., Risberg, B., & Gatenholm, P. (2007) · Biomacromolecules · doi:10.1021/bm070343q · Cited by 218
Development of Small‐Diameter Vascular Grafts
Wang, X., Lin, P., Yao, Q., & Chen, C. (2007) · World Journal of Surgery · doi:10.1007/s00268-006-0731-z · Cited by 206
Liu, Y., Vrana, N. E., Cahill, P. A., & McGuinness, G. B. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31310 · Cited by 206
Medical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries
Singh, C., Wong, C., & Wang, X. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6030500 · Cited by 196
“A number of reviews have reported on the mechanical property comparisons of different types of vascular grafts and their clinical performance [6–8].”
BackgroundMa, Z., Hong, Y., Nelson, D. M., Pichamuthu, J. E., Leeson, C. E., & Wagner, W. R. (2011) · Biomacromolecules · doi:10.1021/bm2007218 · Cited by 195
Nitric Oxide: A Guardian for Vascular Grafts?
de Mel, A., Murad, F., & Seifalian, A. M. (2011) · Chemical Reviews · doi:10.1021/cr200008n · Cited by 188
Self-citationLiu, J. C., Heilshorn, S. C., & Tirrell, D. A. (2004) · Biomacromolecules · doi:10.1021/bm034340z · Cited by 187
Kannan, R. Y., Salacinski, H. J., Odlyha, M., Butler, P. E., & Seifalian, A. M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.006 · Cited by 187
Self-citationTsai, E. C., Dalton, P. D., Shoichet, M. S., & Tator, C. H. (2004) · Journal of Neurotrauma · doi:10.1089/0897715041269687 · Cited by 180
“…Dalton et al., 2002; Hung et al., 1981) because a mismatch in mechanical properties between the implant and the surrounding tissue can result in implant failure (Salacinski et al., 2001; Taylor et al., 1999) or can cause the channel to compress or lacerate the relatively soft spinal cord tissue.”
BackgroundA biological hybrid model for collagen-based tissue engineered vascular constructs
Berglund, J. D., Mohseni, M. M., Nerem, R. M., & Sambanis, A. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00506-9 · Cited by 167
Stekelenburg, M., Rutten, M. C. M., Snoeckx, L. H. E. H., & Baaijens, F. P. T. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0183 · Cited by 164
“06%=mmHg and 4–10%, respectively).(23) The presented TE grafts are based on biodegradable PGA.”
3D-printed vascular networks direct therapeutic angiogenesis in ischaemia
Mirabella, T., MacArthur, J. W., Cheng, D., Ozaki, C. K., Woo, Y. J., Yang, M. T., & Chen, C. S. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0083 · Cited by 161
Cheng, J., Wang, C., & Gu, Y. (2019) · Bio-Medical Materials and Engineering · doi:10.3233/bme-191044 · Cited by 45
Metadata
- Authors
- Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J.
- Venue
- Journal of Biomaterials Applications
- Publisher
- SAGE Publications
- Published
- 2001-01
- Volume
- 15
- Issue
- 3
- Pages
- 241-278
- ISSN
- 0885-3282 (ISSN-L)
- 1530-8022
- OpenAlex
- W2148852502
- Cited by
- 399
- References
- 101
- FWCI
- 10.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.