BioXTAS RAW, a software program for high-throughput automated small-angle X-ray scattering data reduction and preliminary analysis
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
A fully open source software program for automated two-dimensional and one-dimensional data reduction and preliminary analysis of isotropic small-angle X-ray scattering (SAXS) data is presented. The program is freely distributed, following the open-source philosophy, and does not rely on any commercial software packages.BioXTAS RAW is a fully automated program that,via an online feature, reads raw two-dimensional SAXS detector output files and processes and plots data as the data files are created during measurement sessions. The software handles all steps in the data reduction. This includes mask creation, radial averaging, error bar calculation, artifact removal, normalization and q calibration. Further data reduction such as background subtraction and absolute intensity scaling is fast and easy via the graphical user interface.BioXTAS RAW also provides preliminary analysis of one-dimensional data in terms of the indirect Fourier transform using the objective Bayesian approach to obtain the pair-distance distribution function, PDDF, and is thereby a free and open-source alternative to existing PDDF estimation software. Apart from the TIFF input format, the program also accepts ASCII-format input files and is currently compatible with one-dimensional data files from SAXS beamlines at a number of synchrotron facilities.BioXTAS RAW is written in Python with C++ extensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-dimensional detector software: From real detector to idealised image or two-theta scan
Hammersley, A. P., Svensson, S. O., Hanfland, M., Fitch, A. N., & Hausermann, D. (1996) · High Pressure Research · doi:10.1080/08957959608201408 · Cited by 4,674 · cited 1×
“The intensity is corrected for solid-angle effects by normalizing by a factor of cos3ð2 Þ, also used by software such as Fit2D (Hammersley et al., 1996).”
MethodSvergun, D. I. (1992) · Journal of Applied Crystallography · doi:10.1107/s0021889892001663 · Cited by 3,759 · cited 1×
“The feature can be used as an alternative to methods provided by Glatter (1977), Svergun et al. (1988) and Svergun (1992) and, in contrast to the software from Glatter and Svergun, this implementation runs fully automatically and is open source and free of charge for all users.”
PRIMUS: a Windows PC-based system for small-angle scattering data analysis
Konarev, P. V., Volkov, V. V., Sokolova, A. V., Koch, M. H. J., & Svergun, D. I. (2003) · Journal of Applied Crystallography · doi:10.1107/s0021889803012779 · Cited by 2,879 · cited 2×
“The format is fully compatible with other reduction software such as, for example, PRIMUS (Konarev et al., 2003).”
MethodA new method for the evaluation of small-angle scattering data
Glatter, O. (1977) · Journal of Applied Crystallography · doi:10.1107/s0021889877013879 · Cited by 1,279 · cited 2×
“The feature can be used as an alternative to methods provided by Glatter (1977), Svergun et al. (1988) and Svergun (1992) and, in contrast to the software from Glatter and Svergun, this implementation runs fully automatically and is open source and free of charge for all users.”
MethodATSAS 2.1, a program package for small-angle scattering data analysis
Konarev, P. V., Petoukhov, M. V., Volkov, V. V., & Svergun, D. I. (2006) · Journal of Applied Crystallography · doi:10.1107/s0021889806004699 · Cited by 609 · cited 2×
“Existing software packages such as the ATSAS (Konarev et al., 2006) package for biological SAXS experiments are widely used by researchers and greatly facilitate the post-analysis process on returning from the beamline.”
MethodSAXS experiments on absolute scale with Kratky systems using water as a secondary standard
Orthaber, D., Bergmann, A., & Glatter, O. (2000) · Journal of Applied Crystallography · doi:10.1107/s0021889899015216 · Cited by 607 · cited 1×
“These include custom scaling, absolute scaling (by a water and empty-cell measurement) (Orthaber et al., 2000), as well as scaling by sample transmission and exposure time as read directly from the TIFF image header.”
MethodSmall-angle-scattering-data treatment by the regularization method
Svergun, D. I., Semenyuk, A. V., & Feigin, L. A. (1988) · Acta Crystallographica Section A Foundations of Crystallography · doi:10.1107/s0108767387011255 · Cited by 290 · cited 2×
“The feature can be used as an alternative to methods provided by Glatter (1977), Svergun et al. (1988) and Svergun (1992) and, in contrast to the software from Glatter and Svergun, this implementation runs fully automatically and is open source and free of charge for all users.”
MethodBayesian estimation of hyperparameters for indirect Fourier transformation in small-angle scattering
Hansen, S. H. (2000) · Journal of Applied Crystallography · doi:10.1107/s0021889800012930 · Cited by 143 · cited 3×
“…the scattering from a dilute solution of particles of maximum size Dmax (Glatter, 1982): IðqÞ ¼ ZDmax 0 pðrÞ sinðqrÞ qr dr: ð5Þ The solution, suggested by Hansen (2000, 2008) and Vestergaard & Hansen (2006), is to apply the Bayesian framework to this inference problem, and calculate the most…”
MethodApplication of Bayesian analysis to indirect Fourier transformation in small-angle scattering
Vestergaard, B., & Hansen, S. H. (2006) · Journal of Applied Crystallography · doi:10.1107/s0021889806035291 · Cited by 78 · cited 1×
“…a dilute solution of particles of maximum size Dmax (Glatter, 1982): IðqÞ ¼ ZDmax 0 pðrÞ sinðqrÞ qr dr: ð5Þ The solution, suggested by Hansen (2000, 2008) and Vestergaard & Hansen (2006), is to apply the Bayesian framework to this inference problem, and calculate the most plausible hypothesis,…”
MethodSelf-citation
Cited by
New developments in the ATSAS program package for small-angle scattering data analysis
Petoukhov, M. V., Franke, D., Shkumatov, A. V., Tria, G., Kikhney, A. G., Gajda, M., Gorba, C., Mertens, H. D. T., Konarev, P. V., & Svergun, D. I. (2012) · Journal of Applied Crystallography · doi:10.1107/s0021889812007662 · Cited by 1,903
Franke, D., Petoukhov, M. V., Konarev, P. V., Panjkovich, A., Tuukkanen, A., Mertens, H. D. T., Kikhney, A. G., Hajizadeh, N. R., Franklin, J. M., Jeffries, C. M., et al. (2017) · Journal of Applied Crystallography · doi:10.1107/s1600576717007786 · Cited by 1,329
Hopkins, J. B., Gillilan, R. E., & Skou, S. (2017) · Journal of Applied Crystallography · doi:10.1107/s1600576717011438 · Cited by 646
Benecke, G., Wagermaier, W., Li, C., Schwartzkopf, M., Flucke, G., Hoerth, R., Zizak, I., Burghammer, M., Metwalli, E., Müller-Buschbaum, P., et al. (2014) · Journal of Applied Crystallography · doi:10.1107/s1600576714019773 · Cited by 333
Crosslinking ionic oligomers as conformable precursors to calcium carbonate
Liu, Z., Shao, C., Jin, B., Zhang, Z., Zhao, Y., Xu, X., & Tang, R. (2019) · Nature · doi:10.1038/s41586-019-1645-x · Cited by 311
Metadata
- Authors
- Nielsen, S. S., Toft, K. N., Snakenborg, D., Jeppesen, M. G., Jacobsen, J. K., Vestergaard, B., Kutter, J. P., & Arleth, L.
- Venue
- Journal of Applied Crystallography
- Published
- 2009-08-08
- Volume
- 42
- Issue
- 5
- Pages
- 959-964
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W1997449658
- Cited by
- 248
- References
- 9
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.