A comparison of a microfocus X-ray source and a conventional sealed tube for crystal structure determination
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Experiments are described in which a direct comparison was made between a conventional 2 kW water-cooled sealed-tube X-ray source and a 30 W air-cooled microfocus source with focusing multilayer optics, using the same goniometer, detector, radiation (Mo K α), crystals and software. The beam characteristics of the two sources were analyzed and the quality of the resulting data sets compared. The Incoatec Microfocus Source (IµS) gave a narrow approximately Gaussian-shaped primary beam profile, whereas the Bruker AXS sealed-tube source, equipped with a graphite monochromator and a monocapillary collimator, had a broader beam with an approximate intensity plateau. Both sources were mounted on the same Bruker D8 goniometer with a SMART APEX II CCD detector and Bruker Kryoflex low-temperature device. Switching between sources simply required changing the software zero setting of the 2θ circle and could be performed in a few minutes, so it was possible to use the same crystal for both sources without changing its temperature or orientation. A representative cross section of compounds (organic, organometallic and salt) with and without heavy atoms was investigated. For each compound, two data sets, one from a small and one from a large crystal, were collected using each source. In another experiment, the data quality was compared for crystals of the same compound that had been chosen so that they had dimensions similar to the width of the beam. The data were processed and the structures refined using standard Bruker and SHELX software. The experiments show that the IµS gives superior data for small crystals whereas the diffracted intensities were comparable for the large crystals. Appropriate scaling is particularly important for the IµS data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sheldrick, G. M. (2008) · Acta Crystallographica Section A Foundations of Crystallography · doi:10.1107/s0108767307043930 · Cited by 87,804 · cited 1×
“The structures were solved by direct methods (SHELXS97) and refined by full-matrix least-squares against F 2 (SHELXL97) (Sheldrick, 2008).”
MethodSelf-citationFocusing optics for laboratory sources in X-ray crystallography
Arndt, U. W. (1990) · Journal of Applied Crystallography · doi:10.1107/s0021889890000334 · Cited by 29 · cited 2×
“In contrast to total reflection mirrors (Arndt et al., 1998) and capillary optics (Hofmann et al., 2001), graded multilayer mirrors (Göbel, 1982; Arndt, 1990; Jiang et al., 2002) can simultaneously focus and monochromate an X-ray beam.”
BackgroundColes, S. J., & Hursthouse, M. B. (2004) · Journal of Applied Crystallography · doi:10.1107/s0021889804025166 · Cited by 8 · cited 1×
“The development of graded multilayer mirrors for Mo K radiation (Storm et al., 2004; Coles & Hursthouse, 2004) provides an attractive alternative to the conventional sealed-tube sources with graphite monochromators that are still used for the majority of small-molecule single-crystal structure…”
Background
Cited by
Krause, L., Herbst-Irmer, R., Sheldrick, G. M., & Stalke, D. (2015) · Journal of Applied Crystallography · doi:10.1107/s1600576714022985 · Cited by 4,983
Self-citationChanging and challenging times for service crystallography
Coles, S. J., & Gale, P. A. (2012) · Chem. Sci. · doi:10.1039/c2sc00955b · Cited by 447
Conversion of a Singlet Silylene to a stable Biradical
Mondal, K. C., Roesky, H. W., Schwarzer, M. C., Frenking, G., Tkach, I., Wolf, H., Kratzert, D., Herbst‐Irmer, R., Niepötter, B., & Stalke, D. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201204487 · Cited by 174
Self-citation
Metadata
- Authors
- Schulz, T., Meindl, K., Leusser, D., Stern, D., Graf, J., Michaelsen, C., Ruf, M., Sheldrick, G. M., & Stalke, D.
- Venue
- Journal of Applied Crystallography
- Published
- 2009-09-08
- Volume
- 42
- Issue
- 5
- Pages
- 885-891
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2029506883
- Cited by
- 204
- References
- 3
- FWCI
- 10.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.