The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Implementation and performance of SIBYLS: a dual endstation small-angle X-ray scattering and macromolecular crystallography beamline at the Advanced Light Source
Open accessAbstract
The SIBYLS beamline (12.3.1) of the Advanced Light Source at Lawrence Berkeley National Laboratory, supported by the US Department of Energy and the National Institutes of Health, is optimized for both small-angle X-ray scattering (SAXS) and macromolecular crystallography (MX), making it unique among the world's mostly SAXS or MX dedicated beamlines. Since SIBYLS was commissioned, assessments of the limitations and advantages of a combined SAXS and MX beamline have suggested new strategies for integration and optimal data collection methods and have led to additional hardware and software enhancements. Features described include a dual mode monochromator [containing both Si(111) crystals and Mo/B 4 C multilayer elements], rapid beamline optics conversion between SAXS and MX modes, active beam stabilization, sample-loading robotics, and mail-in and remote data collection. These features allow users to gain valuable insights from both dynamic solution scattering and high-resolution atomic diffraction experiments performed at a single synchrotron beamline. Key practical issues considered for data collection and analysis include radiation damage, structural ensembles, alternative conformers and flexibility. SIBYLS develops and applies efficient combined MX and SAXS methods that deliver high-impact results by providing robust cost-effective routes to connect structures to biology and by performing experiments that aid beamline designs for next generation light sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
First lasing and operation of an ångstrom-wavelength free-electron laser
Emma, P., Akre, R., Arthur, J., Bionta, R., Bostedt, C., Bozek, J., Brachmann, A., Bucksbaum, P., Coffee, R., Decker, F.-J., et al. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.176 · Cited by 3,167
Rambo, R. P., & Tainer, J. A. (2011) · Biopolymers · doi:10.1002/bip.21638 · Cited by 533
Self-citationFan, L., Fuss, J. O., Cheng, Q. J., Arvai, A. S., Hammel, M., Roberts, V. A., Cooper, P. K., & Tainer, J. A. (2008) · Cell · doi:10.1016/j.cell.2008.04.030 · Cited by 369
Self-citationStructure of the Autoinhibited Kinase Domain of CaMKII and SAXS Analysis of the Holoenzyme
Rosenberg, O. S., Deindl, S., Sung, R.-J., Nairn, A. C., & Kuriyan, J. (2005) · Cell · doi:10.1016/j.cell.2005.10.029 · Cited by 333
Hitomi, K., Iwai, S., & Tainer, J. A. (2007) · DNA Repair · doi:10.1016/j.dnarep.2006.10.004 · Cited by 220 · cited 1×
“During DNA repair, intermediates are protected by tight product binding and by direct handoff from one repair step to the next (Hitomi et al., 2007).”
BackgroundSelf-citationHammel, M., Rey, M., Yu, Y., Mani, R. S., Classen, S., Liu, M., Pique, M. E., Fang, S., Mahaney, B. L., Weinfeld, M., et al. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.272641 · Cited by 179
Self-citationFuss, J. O., & Tainer, J. A. (2011) · DNA Repair · doi:10.1016/j.dnarep.2011.04.028 · Cited by 170 · cited 2×
“Lesion binding by ATL directs the repair response from base repair by a single protein to nucleotide excision repair that removes a patch of 30 bases and requires the coordination of helicases and nucleases (Fuss & Tainer, 2011).”
BackgroundSelf-citationXLF regulates filament architecture of the XRCC4.ligase IV complex
Hammel, M., Yu, Y., Fang, S., Lees-Miller, S. P., & Tainer, J. A. (2010) · Structure · doi:10.1016/j.str.2010.09.009 · Cited by 116
Self-citation
Cited by
Franke, D., Petoukhov, M. V., Konarev, P. V., Panjkovich, A., Tuukkanen, A., Mertens, H. D. T., Kikhney, A. G., Hajizadeh, N. R., Franklin, J. M., Jeffries, C. M., et al. (2017) · Journal of Applied Crystallography · doi:10.1107/s1600576717007786 · Cited by 1,329
ATSAS 3.0: expanded functionality and new tools for small-angle scattering data analysis
Manalastas-Cantos, K., Konarev, P. V., Hajizadeh, N. R., Kikhney, A. G., Petoukhov, M. V., Molodenskiy, D. S., Panjkovich, A., Mertens, H. D. T., Gruzinov, A., Borges, C., et al. (2021) · Journal of Applied Crystallography · doi:10.1107/s1600576720013412 · Cited by 964
Exploring the repeat protein universe through computational protein design
Brunette, T., Parmeggiani, F., Huang, P.-S., Bhabha, G., Ekiert, D. C., Tsutakawa, S. E., Hura, G. L., Tainer, J. A., & Baker, D. (2015) · Nature · doi:10.1038/nature16162 · Cited by 258
Self-citationPerchlorate Reductase Is Distinguished by Active Site Aromatic Gate Residues
Youngblut, M. D., Tsai, C.-L., Clark, I. C., Carlson, H. K., Maglaqui, A. P., Gau-Pan, P. S., Redford, S. A., Wong, A., Tainer, J. A., & Coates, J. D. (2016) · Journal of Biological Chemistry · doi:10.1074/jbc.m116.714618 · Cited by 88
Self-citationRNA-guided assembly of Rev-RRE nuclear export complexes
Bai, Y., Tambe, A., Zhou, K., & Doudna, J. A. (2014) · eLife · doi:10.7554/elife.03656 · Cited by 86
Metadata
- Authors
- Classen, S., Hura, G. L., Holton, J. M., Rambo, R. P., Rodic, I., McGuire, P. J., Dyer, K., Hammel, M., Meigs, G., Frankel, K. A., & Tainer, J. A.
- Venue
- Journal of Applied Crystallography
- Published
- 2013-01-17
- Volume
- 46
- Issue
- 1
- Pages
- 1-13
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2145707329
- Cited by
- 251
- References
- 8
- FWCI
- 10.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation and performance of SIBYLS: a dual endstation small-angle X-ray scattering and macromolecular crystallography beamline at the Advanced Light Source. https://app.cochat.ai/papers/10.1107/s0021889812048698
- The paper
- Classen, S., Hura, G. L., Holton, J. M., Rambo, R. P., Rodic, I., McGuire, P. J., Dyer, K., Hammel, M., Meigs, G., Frankel, K. A., & Tainer, J. A. (2013). Implementation and performance of SIBYLS: a dual endstation small-angle X-ray scattering and macromolecular crystallography beamline at the Advanced Light Source. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889812048698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.