Measurement errors and their consequences in protein crystallography
Open accessThe DOI matches its Crossref record.
Abstract
This article analyzes the relative impact of various types of measurement uncertainties on different stages of structure determination. The treatment of errors is an important part of the experimental process and becomes critical when data quality is barely sufficient to solve and/or answer detailed questions about the structure. The sources and types of experimental errors are described and methods of minimizing their impact are discussed. Practical calculations of sigma estimates in DENZO and SCALEPACK are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Krause, L., Herbst-Irmer, R., Sheldrick, G. M., & Stalke, D. (2015) · Journal of Applied Crystallography · doi:10.1107/s1600576714022985 · Cited by 4,983
Crystal structure of the human sterol transporter ABCG5/ABCG8
Lee, J.-Y., Kinch, L. N., Borek, D. M., Wang, J., Wang, J., Urbatsch, I. L., Xie, X.-S., Grishin, N. V., Cohen, J. C., Otwinowski, Z., et al. (2016) · Nature · doi:10.1038/nature17666 · Cited by 269
Self-citationProtein AMPylation by an Evolutionarily Conserved Pseudokinase
Sreelatha, A., Yee, S. S., Lopez, V. A., Park, B. C., Kinch, L. N., Pilch, S., Servage, K. A., Zhang, J., Jiou, J., Karasiewicz-Urbańska, M., et al. (2018) · Cell · doi:10.1016/j.cell.2018.08.046 · Cited by 195
“, 2006) with applied corrections for effects resulting from absorption in a crystal and for radiation damage (Borek et al., 2003; Otwinowski et al., 2003), the calculation of an optimal error model, and corrections to compensate the phasing signal for a radiation-induced increase of non-isomorphism within the crystal…”
BackgroundMolecular Discrimination between Two Conformations of Sphingomyelin in Plasma Membranes
Endapally, S., Frias, D., Grzemska, M., Gay, A., Tomchick, D. R., & Radhakrishnan, A. (2019) · Cell · doi:10.1016/j.cell.2018.12.042 · Cited by 168
Xu, J., Camacho, M., Xu, Y., Esser, V., Liu, X., Trimbuch, T., Pan, Y.-Z., Ma, C., Tomchick, D. R., Rosenmund, C., et al. (2017) · eLife · doi:10.7554/elife.22567 · Cited by 119
“, 2006), with applied corrections for effects resulting from absorption in a crystal and for radiation damage (Borek et al., 2003; Otwinowski et al., 2003), the calculation of an optimal error model, and corrections to compensate the phasing signal for a radiation-induced increase of non-isomorphism within the crystal…”
BackgroundMethod
Metadata
- Authors
- Borek, D., Minor, W., & Otwinowski, Z.
- Venue
- Acta Crystallographica Section D Biological Crystallography
- Published
- 2003-10-23
- Volume
- 59
- Issue
- 11
- Pages
- 2031-2038
- ISSN
- 0907-4449 (ISSN-L)
- OpenAlex
- W2170209795
- Cited by
- 71
- References
- 0
- FWCI
- 0.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement errors and their consequences in protein crystallography. https://app.cochat.ai/papers/10.1107/s0907444903020924
- The paper
- Borek, D., Minor, W., & Otwinowski, Z. (2003). Measurement errors and their consequences in protein crystallography. Acta Crystallographica Section D Biological Crystallography. https://doi.org/10.1107/s0907444903020924
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.