Re-refinement from deposited X-ray data can deliver improved models for most PDB entries
Open accessThe DOI matches its Crossref record.
Abstract
The deposition of X-ray data along with the customary structural models defining PDB entries makes it possible to apply large-scale re-refinement protocols to these entries, thus giving users the benefit of improvements in X-ray methods that have occurred since the structure was deposited. Automated gradient refinement is an effective method to achieve this goal, but real-space intervention is most often required in order to adequately address problems detected by structure-validation software. In order to improve the existing protocol, automated re-refinement was combined with structure validation and difference-density peak analysis to produce a catalogue of problems in PDB entries that are amenable to automatic correction. It is shown that re-refinement can be effective in producing improvements, which are often associated with the systematic use of the TLS parameterization of B factors, even for relatively new and high-resolution PDB entries, while the accompanying manual or semi-manual map analysis and fitting steps show good prospects for eventual automation. It is proposed that the potential for simultaneous improvements in methods and in re-refinement results be further encouraged by broadening the scope of depositions to include refinement metadata and ultimately primary rather than reduced X-ray data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Linking Crystallographic Model and Data Quality
Karplus, P. A., & Diederichs, K. (2012) · Science · doi:10.1126/science.1218231 · Cited by 1,781
Tools for macromolecular model building and refinement into electron cryo-microscopy reconstructions
Brown, A., Long, F., Nicholls, R. A., Toots, J., Emsley, P., & Murshudov, G. (2015) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s1399004714021683 · Cited by 618
Determination of Ensemble-Average Pairwise Root Mean-Square Deviation from Experimental B-Factors
Kuzmanic, A., & Zagrovic, B. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2009.11.011 · Cited by 447
PDB_REDO: automated re-refinement of X-ray structure models in the PDB
Joosten, R. P., Salzemann, J., Bloch, V., Stockinger, H., Berglund, A.-C., Blanchet, C., Bongcam-Rudloff, E., Combet, C., Da Costa, A. L., Deleage, G., et al. (2009) · Journal of Applied Crystallography · doi:10.1107/s0021889809008784 · Cited by 236
Self-citationPDB_REDO: constructive validation, more than just looking for errors
Joosten, R. P., Joosten, K., Murshudov, G. N., & Perrakis, A. (2012) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444911054515 · Cited by 213
Self-citation
Metadata
- Authors
- Joosten, R. P., Womack, T., Vriend, G., & Bricogne, G.
- Venue
- Acta Crystallographica Section D Biological Crystallography
- Published
- 2009-01-20
- Volume
- 65
- Issue
- 2
- Pages
- 176-185
- ISSN
- 0907-4449 (ISSN-L)
- OpenAlex
- W2113794015
- Cited by
- 80
- References
- 0
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Re-refinement from deposited X-ray data can deliver improved models for most PDB entries. https://app.cochat.ai/papers/10.1107/s0907444908037591
- The paper
- Joosten, R. P., Womack, T., Vriend, G., & Bricogne, G. (2009). Re-refinement from deposited X-ray data can deliver improved models for most PDB entries. Acta Crystallographica Section D Biological Crystallography. https://doi.org/10.1107/s0907444908037591
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.