CoChat

ID29: a high-intensity highly automated ESRF beamline for macromolecular crystallography experiments exploiting anomalous scattering

Open access
de Sanctis, Daniele, Beteva, Antonia, Caserotto, Hugo, Dobias, Fabien, Gabadinho, José, Giraud, Thierry, Gobbo, Alexandre, Guijarro, Matias, Lentini, Mario, Lavault, Bernard, Mairs, Trevor, McSweeney, Seán, Petitdemange, Sébastien, Rey-Bakaikoa, Vicente, Surr, John, Theveneau, Pascal, Leonard, Gordon A., Mueller-Dieckmann, Christoph · 2012 · Journal of Synchrotron Radiation
Cited by 182

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

ID29 is an ESRF undulator beamline with a routinely accessible energy range of between 20.0 keV and 6.0 keV (λ = 0.62 Å to 2.07 Å) dedicated to the use of anomalous dispersion techniques in macromolecular crystallography. Since the beamline was first commissioned in 2001, ID29 has, in order to provide an improved service to both its academic and proprietary users, been the subject of almost continuous upgrade and refurbishment. It is now also the home to the ESRF Cryobench facility, ID29S. Here, the current status of the beamline is described and plans for its future are briefly outlined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s0909049512009715

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • The Protein Data Bank

    Berman, H. M. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.1.235 · Cited by 40,196

  • XDS

    Kabsch, W. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909047337 · Cited by 16,463

  • The integration of macromolecular diffraction data

    Leslie, A. G. W. (2006) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444905039107 · Cited by 1,341

  • The PILATUS 1M detector

    Broennimann, C., Eikenberry, E. F., Henrich, B., Horisberger, R., Huelsen, G., Pohl, E., Schmitt, B., Schulze‐Briese, C., Suzuki, M., Tomizaki, T., et al. (2006) · Journal of Synchrotron Radiation · doi:10.1107/s0909049505038665 · Cited by 488 · cited 1×

    “The extremely fast readout ( 2 ms) of the detector coupled with a possible 12 Hz frame rate also allows for the collection of diffraction data in a continuous rotation, a so-called shutterless mode (Hülsen et al., 2006; Broennimann et al., 2006), coupled with fine ’-sliced oscillation images.”
    Background
  • MxCuBE: a synchrotron beamline control environment customized for macromolecular crystallography experiments

    Gabadinho, J., Beteva, A., Guijarro, M., Rey-Bakaikoa, V., Spruce, D., Bowler, M. W., Brockhauser, S., Flot, D., Gordon, E. J., Hall, D. R., et al. (2010) · Journal of Synchrotron Radiation · doi:10.1107/s0909049510020005 · Cited by 229 · cited 6×

    “Diffractometer MD2 microdiffractometer (MAATEL, Voreppe, France; Perrakis et al., 1999); BGO, scintillator crystal for beam visualization at the sample position Sample changer Grenoble SC3 (Cipriani et al., 2006); 50 sample capacity; SPINE standard sample holders; unloading/loading/ automatic loop centring 70 s Fast s…”
    MethodInfluentialSelf-citation
  • EDNA: a framework for plugin-based applications applied to X-ray experiment online data analysis

    Incardona, M.-F., Bourenkov, G. P., Levik, K., Pieritz, R. A., Popov, A. N., & Svensson, O. (2009) · Journal of Synchrotron Radiation · doi:10.1107/s0909049509036681 · Cited by 228 · cited 3×

    “Photon flux at the sample position (see above) is both displayed in the MxCuBE GUI and automatically passed to EDNA/BEST crystal characterization (Incardona et al., 2009; Bourenkov & Popov, 2010) when this is run from the GUI.”
    Method
  • The ID23-2 structural biology microfocus beamline at the ESRF

    Flot, D., Mairs, T., Giraud, T., Guijarro, M., Lesourd, M., Rey, V., van Brussel, D., Morawe, C., Borel, C., Hignette, O., et al. (2010) · Journal of Synchrotron Radiation · doi:10.1107/s0909049509041168 · Cited by 209

    Self-citation
  • ISPyB: an information management system for synchrotron macromolecular crystallography

    Delageniere, S., Brenchereau, P., Launer, L., Ashton, A., Leal, R. M. F., Veyrier, S., Gabadinho, J., Gordon, E. J., Jones, S. D., Levik, K., et al. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btr535 · Cited by 182 · cited 3×

    “…allows for remote operation Crystal characterization EDNA (Incardona et al., 2009), BEST (Bourenkov & Popov, 2010) Beamline database ISPyB (Beteva et al., 2006; Delagenière et al., 2011) This calibration is repeated at different energies and for the different beam-defining apertures (see below).”
    MethodSelf-citation
  • The ID23-1 structural biology beamline at the ESRF

    Nurizzo, D., Mairs, T., Guijarro, M., Rey‐Bakaikoa, V., Meyer, J., Fajardo, P., Chavanne, J., Biasci, J.-C., McSweeney, S. M., & Mitchell, E. P. (2006) · Journal of Synchrotron Radiation · doi:10.1107/s0909049506004341 · Cited by 177 · cited 4×

    “Focusing of the X-ray beam is achieved using an Rh-coated toroidal mirror equipped with a pneumatically driven bender (see Nurizzo et al., 2006, for full details).”
    MethodInfluentialSelf-citation
  • Automation of sample mounting for macromolecular crystallography

    Cipriani, F., Felisaz, F., Launer, L., Aksoy, J., Caserotto, H., Cusack, S., Dallery, M., di-Chiaro, F., Guijarro, M., Huet, J., et al. (2006) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444906030587 · Cited by 111 · cited 3×

    “Diffractometer MD2 microdiffractometer (MAATEL, Voreppe, France; Perrakis et al., 1999); BGO, scintillator crystal for beam visualization at the sample position Sample changer Grenoble SC3 (Cipriani et al., 2006); 50 sample capacity; SPINE standard sample holders; unloading/loading/ automatic loop centring 70 s Fast s…”
    BackgroundMethodSelf-citation

Show all 18 references

Cited by

Metadata

Authors
de Sanctis, D., Beteva, A., Caserotto, H., Dobias, F., Gabadinho, J., Giraud, T., Gobbo, A., Guijarro, M., Lentini, M., Lavault, B., Mairs, T., McSweeney, S., Petitdemange, S., Rey-Bakaikoa, V., Surr, J., Theveneau, P., Leonard, G. A., & Mueller-Dieckmann, C.
Venue
Journal of Synchrotron Radiation
Published
2012-03-31
Volume
19
Issue
3
Pages
455-461
ISSN
  • 0909-0495 (ISSN-L)
  • 1600-5775
OpenAlex
W2052022792
Cited by
182
References
18
FWCI
7.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.