Room-temperature serial crystallography at synchrotron X-ray sources using slowly flowing free-standing high-viscosity microstreams
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Recent advances in synchrotron sources, beamline optics and detectors are driving a renaissance in room-temperature data collection. The underlying impetus is the recognition that conformational differences are observed in functionally important regions of structures determined using crystals kept at ambient as opposed to cryogenic temperature during data collection. In addition, room-temperature measurements enable time-resolved studies and eliminate the need to find suitable cryoprotectants. Since radiation damage limits the high-resolution data that can be obtained from a single crystal, especially at room temperature, data are typically collected in a serial fashion using a number of crystals to spread the total dose over the entire ensemble. Several approaches have been developed over the years to efficiently exchange crystals for room-temperature data collection. These include in situ collection in trays, chips and capillary mounts. Here, the use of a slowly flowing microscopic stream for crystal delivery is demonstrated, resulting in extremely high-throughput delivery of crystals into the X-ray beam. This free-stream technology, which was originally developed for serial femtosecond crystallography at X-ray free-electron lasers, is here adapted to serial crystallography at synchrotrons. By embedding the crystals in a high-viscosity carrier stream, high-resolution room-temperature studies can be conducted at atmospheric pressure using the unattenuated X-ray beam, thus permitting the analysis of small or weakly scattering crystals. The high-viscosity extrusion injector is described, as is its use to collect high-resolution serial data from native and heavy-atom-derivatized lysozyme crystals at the Swiss Light Source using less than half a milligram of protein crystals. The room-temperature serial data allow de novo structure determination. The crystal size used in this proof-of-principle experiment was dictated by the available flux density. However, upcoming developments in beamline optics, detectors and synchrotron sources will enable the use of true microcrystals. This high-throughput, high-dose-rate methodology provides a new route to investigating the structure and dynamics of macromolecules at ambient temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phaser crystallographic software
McCoy, A. J., Grosse-Kunstleve, R. W., Adams, P. D., Winn, M. D., Storoni, L. C., & Read, R. J. (2007) · Journal of Applied Crystallography · doi:10.1107/s0021889807021206 · Cited by 20,612 · cited 2×
“Molecular replacement was performed using Phaser 2.4.1 (McCoy et al., 2007) using data between 15 and 2.5 Å resolution.”
MethodInfluentialKabsch, W. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909047337 · Cited by 16,463
Self-citationREFMAC 5 for the refinement of macromolecular crystal structures
Murshudov, G. N., Skubák, P., Lebedev, A. A., Pannu, N. S., Steiner, R. A., Nicholls, R. A., Winn, M. D., Long, F., & Vagin, A. A. (2011) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444911001314 · Cited by 8,317
Femtosecond X-ray protein nanocrystallography
Chapman, H. N., Fromme, P., Barty, A., White, T. A., Kirian, R. A., Aquila, A., Hunter, M. S., Schulz, J., DePonte, D. P., Weierstall, U., et al. (2011) · Nature · doi:10.1038/nature09750 · Cited by 2,086 · cited 1×
“…crystallography (SFX) at X-ray FELs allows the acquisition of high-resolution undamaged snapshot diffraction patterns at ambient temperature (Chapman et al., 2011; Boutet et al., 2012) by constantly supplying fresh crystals in a liquid microjet (Weierstall et al., 2012, 2014; Sierra et al.,…”
BackgroundSelf-citationLinking Crystallographic Model and Data Quality
Karplus, P. A., & Diederichs, K. (2012) · Science · doi:10.1126/science.1218231 · Cited by 1,781 · cited 2×
“CC1/2 is the percentage of correlation between intensities from random half data sets (Karplus & Diederichs, 2012).”
BackgroundMethodInfluentialAutomated macromolecular model building for X-ray crystallography using ARP/wARP version 7
Langer, G., Cohen, S. X., Lamzin, V. S., & Perrakis, A. (2008) · Nature Protocols · doi:10.1038/nprot.2008.91 · Cited by 1,606 · cited 1×
“However, the nXDS data allowed an almost complete model to be automatically built by ARP/ wARP (Langer et al., 2008), whereas for the CrystFEL data only about 50% of the structure could be built automatically.”
MethodAutomated Structure Solution With autoSHARP
Vonrhein, C., Blanc, E., Roversi, P., & Bricogne, G. (2006) · Macromolecular Crystallography Protocols, Volume 2 · doi:10.1385/1-59745-266-1:215 · Cited by 963 · cited 2×
“Phasing by multiple isomorphous replacement with anomalous scattering (MIRAS) was performed with autoSHARP (Vonrhein et al., 2007), using the 1.32 Å wavelength data as a native data set (using data from 15 to 2.5 Å resolution) and the data from iodide-soaked and gold-soaked crystals (see above)…”
MethodInfluentialHigh-Resolution Protein Structure Determination by Serial Femtosecond Crystallography
Boutet, S., Lomb, L., Williams, G. J., Barends, T. R. M., Aquila, A., Doak, R. B., Weierstall, U., DePonte, D. P., Steinbrener, J., Shoeman, R. L., et al. (2012) · Science · doi:10.1126/science.1217737 · Cited by 857 · cited 12×
“CCano is the mean correlation factor between two random subsets of anomalous intensity differences. dose rotation data collected using synchrotron radiation from similarly grown macroscopic lysozyme crystals kept at room temperature and concluded that there is reasonable agreement between the data and no indication of…”
BackgroundMethodInfluentialSelf-citationImproved R-factors for diffraction data analysis in macromolecular crystallography
Diederichs, K., & Karplus, P. A. (1997) · Nature Structural Biology · doi:10.1038/nsb0497-269 · Cited by 838 · cited 1×
“See Diederichs & Karplus (1997) for definition.”
Global indicators of X-ray data quality
Weiss, M. S. (2001) · Journal of Applied Crystallography · doi:10.1107/s0021889800018227 · Cited by 684
Cited by
Linac Coherent Light Source: The first five years
Bostedt, C., Boutet, S., Fritz, D. M., Huang, Z., Lee, H. J., Lemke, H. T., Robert, A., Schlotter, W. F., Turner, J. J., & Williams, G. J. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.015007 · Cited by 618
Serial femtosecond crystallography: the first five years
Schlichting, I. (2015) · IUCrJ · doi:10.1107/s205225251402702x · Cited by 308
Self-citationWeinert, T., Olieric, N., Cheng, R., Brünle, S., James, D., Ozerov, D., Gashi, D., Vera, L., Marsh, M., Jaeger, K., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00630-4 · Cited by 252
Self-citationXFELs for structure and dynamics in biology
Spence, J. C. H. (2017) · IUCrJ · doi:10.1107/s2052252517005760 · Cited by 177
“In order to conserve precious protein, viscous jets were developed (Weierstall et al., 2014; Botha et al., 2015; Conrad et al., 2015) using a medium with the high viscosity of automobile grease, which emerges slowly from the nozzle.”
BackgroundX-Ray Free-Electron Lasers for the Structure and Dynamics of Macromolecules
Chapman, H. N. (2019) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-013118-110744 · Cited by 174
The Coherent X-ray Imaging instrument at the Linac Coherent Light Source
Liang, M., Williams, G. J., Messerschmidt, M., Seibert, M. M., Montanez, P. A., Hayes, M., Milathianaki, D., Aquila, A., Hunter, M. S., Koglin, J. E., et al. (2015) · Journal of Synchrotron Radiation · doi:10.1107/s160057751500449x · Cited by 171
“Other slower flowing jets such as an electrospinning source (Sierra et al., 2012), a lipidic cubic phase jet (Weierstall et al., 2014) as well as other high-viscosity carrier media (Botha et al., 2015) are all used to form flowing columns of sample at various speeds.”
BackgroundIndications of radiation damage in ferredoxin microcrystals using high-intensity X-FEL beams
Nass, K., Foucar, L., Barends, T. R. M., Hartmann, E., Botha, S., Shoeman, R. L., Doak, R. B., Alonso-Mori, R., Aquila, A., Bajt, S., et al. (2015) · Journal of Synchrotron Radiation · doi:10.1107/s1600577515002349 · Cited by 131
“Note that we have shown previously that undamaged SFX data of lysozyme microcrystals agree well with the corresponding synchrotron rotation data of large crystals (Boutet et al., 2012) as well as with synchrotron serial crystallography data of small crystals (Botha et al., 2015).”
ResultSelf-citationWatching proteins function with time-resolved x-ray crystallography
Šrajer, V., & Schmidt, M. (2017) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/aa7d32 · Cited by 67
Wranik, M., Kepa, M. W., Beale, E. V., James, D., Bertrand, Q., Weinert, T., Furrer, A., Glover, H., Gashi, D., Carrillo, M., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-43523-5 · Cited by 14
Self-citation
Metadata
- Authors
- Botha, S., Nass, K., Barends, T. R. M., Kabsch, W., Latz, B., Dworkowski, F., Foucar, L., Panepucci, E., Wang, M., Shoeman, R. L., Schlichting, I., & Doak, R. B.
- Venue
- Acta Crystallographica Section D Biological Crystallography
- Published
- 2015-01-23
- Volume
- 71
- Issue
- 2
- Pages
- 387-397
- ISSN
- 0907-4449 (ISSN-L)
- 1399-0047
- OpenAlex
- W2061036164
- Cited by
- 215
- References
- 45
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.