Aquarium: an automatic data-processing and experiment information management system for biological macromolecular crystallography beamlines
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
With the popularity of hybrid pixel array detectors, hundreds of diffraction data sets are collected at a biological macromolecular crystallography (MX) beamline every day. Therefore, the manual processing and recording procedure will be a very time-consuming and error-prone task. Aquarium is an automatic data processing and experiment information management system designed for synchrotron radiation source MX beamlines. It is composed of a data processing module, a daemon module and a web site module. Before experiments, the sample information can be registered into a database. The daemon module will submit data processing jobs to a high-performance cluster as soon as the data set collection is completed. The data processing module will automatically process data sets from data reduction to model building if the anomalous signal is available. The web site module can be used to monitor and inspect the data processing results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of the CCP 4 suite and current developments
Winn, M. D., Ballard, C. C., Cowtan, K. D., Dodson, E. J., Emsley, P., Evans, P. R., Keegan, R. M., Krissinel, E. B., Leslie, A. G. W., McCoy, A., et al. (2011) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910045749 · Cited by 12,353
Linking Crystallographic Model and Data Quality
Karplus, P. A., & Diederichs, K. (2012) · Science · doi:10.1126/science.1218231 · Cited by 1,781
NGL Viewer: a web application for molecular visualization
Rose, A. S., & Hildebrand, P. W. (2015) · Nucleic Acids Research · doi:10.1093/nar/gkv402 · Cited by 462
Cited by
Structure of the SARS-CoV-2 spike receptor-binding domain bound to the ACE2 receptor
Lan, J., Ge, J., Yu, J., Shan, S., Zhou, H., Fan, S., Zhang, Q., Shi, X., Wang, Q., Zhang, L., et al. (2020) · Nature · doi:10.1038/s41586-020-2180-5 · Cited by 5,983
Self-citationWang, R., Zhang, Q., Ge, J., Ren, W., Zhang, R., Lan, J., Ju, B., Su, B., Yu, F., Chen, P., et al. (2021) · Immunity · doi:10.1016/j.immuni.2021.06.003 · Cited by 240
Self-citationAccurate prediction of CDR-H3 loop structures of antibodies with deep learning
(2024) · doi:10.7554/elife.91512.4 · Cited by 16
H3-OPT: Accurate prediction of CDR-H3 loop structures of antibodies with deep learning
Chen, H., Fan, X., Zhu, S., Pei, Y., Zhang, X., Zhang, X., Liu, L., Qian, F., & Tian, B. (2023) · doi:10.1101/2023.08.19.553933 · Cited by 1
Metadata
- Authors
- Yu, F., Wang, Q., Li, M., Zhou, H., Liu, K., Zhang, K., Wang, Z., Xu, Q., Xu, C., Pan, Q., & He, J.
- Venue
- Journal of Applied Crystallography
- Published
- 2019-03-14
- Volume
- 52
- Issue
- 2
- Pages
- 472-477
- ISSN
- 0021-8898 (ISSN-L)
- 1600-5767
- OpenAlex
- W2921744738
- Cited by
- 114
- References
- 3
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.