The DLR MIRO: a versatile lightweight robot for surgical applications
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Purpose: Surgical robotics can be divided into two groups: specialized and versatile systems. Versatile systems can be used in different surgical applications, control architectures and operating room set‐ups, but often still based on the adaptation of industrial robots. Space consumption, safety and adequacy of industrial robots in the unstructured and crowded environment of an operating room and in close human robot interaction are at least questionable. The purpose of this paper is to describe the DLR MIRO, a new versatile lightweight robot for surgical applications. Design/methodology/approach: The design approach of the DLR MIRO robot focuses on compact, slim and lightweight design to assist the surgeon directly at the operating table without interference. Significantly reduced accelerated masses (total weight 10 kg) enhance the safety of the system during close interaction with patient and user. Additionally, MIRO integrates torque‐sensing capabilities to enable close interaction with human beings in unstructured environments. Findings: A payload of 30 N, optimized kinematics and workspace for surgery enable a broad range of possible applications. Offering position, torque and impedance control on Cartesian and joint level, the robot can be integrated easily into telepresence (e.g. endoscopic surgery), autonomous or soft robotics applications, with one or multiple arms. Originality/value: This paper considers lightweight and compact design as important design issues in robotic assistance systems for surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Robotics mechanics and Control
Craig, J. (1986) · Cited by 5,024
Albu-Schäffer, A., Ott, C., & Hirzinger, G. (2007) · The International Journal of Robotics Research · doi:10.1177/0278364907073776 · Cited by 815 · cited 10×
“The Denavit-Hartenberg parameters of the optimized kinematics are shown in The integration of all hardware features established by the DLR LWR (torque and PSs, safety brakes, integrated electronics, etc.) in a yet more slim design with dedicated groups of joints with intersecting axes is the most challenging aspect in…”
InfluentialSelf-citationDLR-Hand II: next generation of a dextrous robot hand
Butterfass, J., Grebenstein, M., Liu, H., & Hirzinger, G. (2002) · Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164) · doi:10.1109/robot.2001.932538 · Cited by 808
Self-citationFoundations of robotics: analysis and control
(1991) · Choice Reviews Online · doi:10.5860/choice.28-5104 · Cited by 535
DLR's torque-controlled light weight robot III-are we reaching the technological limits now?
Hirzinger, G., Sporer, N., Albu-Schaffer, A., Hahnle, M., Krenn, R., Pascucci, A., & Schedl, M. (2003) · Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292) · doi:10.1109/robot.2002.1014788 · Cited by 285 · cited 1×
“The design approach of the LWR, with a sequential chain of revolving single joints connected by shell structures (Hirzinger et al., 2002) turned out to be not feasible for the MIRO robot.”
Self-citationPrototype of Instrument for Minimally Invasive Surgery with 6-Axis Force Sensing Capability
Seibold, U., Kübler, B., & Hirzinger, G. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2005.1570167 · Cited by 234 · cited 2×
“notation of Yoshikawa (1990) and Craig (1986).”
Self-citationSafety Evaluation of Physical Human-Robot Interaction via Crash-Testing
Haddadin, S., Albu-Schaeffer, A., & Hirzinger, G. (2007) · Robotics: Science and Systems III · doi:10.15607/rss.2007.iii.028 · Cited by 231 · cited 2×
“Moreover, in case of fast impacts of the robot, only the reflected link inertia of 5.8 kg is relevant (Haddadin et al., 2007), due to the intrinsic joint elasticity.”
InfluentialSelf-citationOtt, C., Albu-Schaffer, A., Kugi, A., Stamigioli, S., & Hirzinger, G. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307462 · Cited by 167 · cited 1×
“Since the robot is a redundant arm with seven DoF, it can still be freely moved in the null-space while having a Cartesian compliance imposed (Ott et al., 2004).”
Self-citationBenefits and challenges for platform-based design
Sangiovanni-Vincentelli, A. L., Carloni, L. P., Bernardinis, F. D., & Sgroi, M. (2004) · ACM/IEEE Design Automation Conference (DAC) · doi:10.1145/996566.996684 · Cited by 156
Green, P. S., Hill, J. W., Jensen, J. F., & Shah, A. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.391769 · Cited by 126 · cited 1×
“Specialized systems focus either on a dedicated surgical technique, like endoscopic surgery with the da Vinci surgical system by Intuitive Surgical (Green et al., 1995) and Artemis (Schurr et al., 1996) or on the treatment of a specific medical disease (e.g. cancer in Phee et al., 2005).”
A hands-on-robot for accurate placement of pedicle screws
Ortmaier, T., Weiss, H., Hagn, U., Grebenstein, M., Nickl, M., Albu‐Schäffer, A., Ott, C., Jörg, S., Konietschke, R., Le-Tien, L., et al. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642345 · Cited by 82 · cited 4×
“drilling machine) and is guided by the surgeon manually, whereas the robot limits the free motion based on preplanned virtual spaces and directions in the form of haptic paths, targets, virtual walls (Ortmaier et al., 2006).”
InfluentialSelf-citationTelemanipulator for remote minimally invasive surgery
Hagn, U., Ortmaier, T., Konietschke, R., Kübler, B., Seibold, U., Tobergte, A., Nickl, M., Jörg, S., & Hirzinger, G. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.929925 · Cited by 71
Self-citationManipulability and Accuracy Measures for a Medical Robot in Minimally Invasive Surgery
Konietschke, R., Ortmaier, T., Weiss, H., Hirzinger, G., & Engelke, R. (2004) · Springer eBooks · doi:10.1007/978-1-4020-2249-4_21 · Cited by 33 · cited 4×
“Based on the different selected medical procedures the kinematics of the robot has been optimized by the means of gradient methods and genetic algorithms (Konietschke et al., 2004).”
InfluentialSelf-citationAdvances in Human-Robot Interaction
Dillmann, R., Stopp, A., Prassler, E., Lawitzky, G., Iossifidis, I., Hägele, M., & Grunwald, G. (2005) · Springer tracts in advanced robotics · doi:10.1007/b97960 · Cited by 33
Cited by
An open-source research kit for the da Vinci® Surgical System
Kazanzides, P., Chen, Z., Deguet, A., Fischer, G. S., Taylor, R. H., & DiMaio, S. P. (2014) · 2014 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2014.6907809 · Cited by 493
In situ bioprinting – Bioprinting from benchside to bedside?
Singh, S., Choudhury, D., Yu, F., Mironov, V., & Naing, M. W. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.045 · Cited by 273
DLR MiroSurge: a versatile system for research in endoscopic telesurgery
Hagn, U., Konietschke, R., Tobergte, A., Nickl, M., Jörg, S., Kübler, B., Passig, G., Gröger, M., Fröhlich, F., Seibold, U., et al. (2010) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0372-4 · Cited by 270
Self-citationSoft Actuators and Robots that Are Resistant to Mechanical Damage
Martinez, R. V., Glavan, A. C., Keplinger, C., Oyetibo, A. I., & Whitesides, G. M. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303676 · Cited by 261
Dentronics: Towards robotics and artificial intelligence in dentistry
Grischke, J., Johannsmeier, L., Eich, L., Griga, L., & Haddadin, S. (2020) · Dental Materials · doi:10.1016/j.dental.2020.03.021 · Cited by 221
Metadata
- Authors
- Hagn, U., Nickl, M., Jörg, S., Passig, G., Bahls, T., Nothhelfer, A., Hacker, F., Le‐Tien, L., Albu‐Schäffer, A., Konietschke, R., Grebenstein, M., Warpup, R., Haslinger, R., Frommberger, M., & Hirzinger, G.
- Venue
- Industrial Robot: An International Journal
- Publisher
- Emerald
- Published
- 2008-06-20
- Volume
- 35
- Issue
- 4
- Pages
- 324-336
- ISSN
- 0143-991X (ISSN-L)
- OpenAlex
- W2008817337
- Cited by
- 188
- References
- 14
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.