The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
A review of gas sensors employed in electronic nose applications
Abstract
This paper reviews the range of sensors used in electronic nose (e‐nose) systems to date. It outlines the operating principles and fabrication methods of each sensor type as well as the applications in which the different sensors have been utilised. It also outlines the advantages and disadvantages of each sensor for application in a cost‐effective low‐power handheld e‐nose system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semiconducting and Metallic Polymers: The Fourth Generation of Polymeric Materials (Nobel Lecture)
Heeger, A. J. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20010716)40:14<2591::aid-anie2591>3.0.co;2-0 · Cited by 1,493
Cross-Reactive Chemical Sensor Arrays
Albert, K. J., Lewis, N. S., Schauer, C. L., Sotzing, G. A., Stitzel, S. E., Vaid, T. P., & Walt, D. R. (2000) · Chemical Reviews · doi:10.1021/cr980102w · Cited by 1,284
Fiber optic sensor technology: an overview
Grattan, K. T. V., & Sun, T. (2000) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(99)00368-4 · Cited by 899
Transport phenomena through polymeric systems
George, S. C., & Thomas, S. (2001) · Progress in Polymer Science · doi:10.1016/s0079-6700(00)00036-8 · Cited by 790
Array-Based Vapor Sensing Using Chemically Sensitive, Carbon Black−Polymer Resistors
Lonergan, M. C., Severin, E. J., Doleman, B. J., Beaber, S. A., Grubbs, R. H., & Lewis, N. S. (1996) · Chemistry of Materials · doi:10.1021/cm960036j · Cited by 633
Diffusion in and through polymers
VIETH, W. R. (1991) · Cited by 521
Handbook of Machine Olfaction: Electronic Nose Technology
(2002) · Wiley eBooks · doi:10.1002/3527601597 · Cited by 498
‘Electronic Noses’ and Their Application to Food
Schaller, E., Bosset, J. O., & Escher, F. (1998) · LWT - Food Science and Technology · doi:10.1006/fstl.1998.0376 · Cited by 446
The how and why of electronic noses
Nagle, H. T., Gutierrez-Osuna, R., & Schiffman, S. S. (1998) · IEEE Spectrum · doi:10.1109/6.715180 · Cited by 438
A chemically diverse conducting polymer-based "electronic nose".
Freund, M. S., & Lewis, N. S. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.7.2652 · Cited by 344
Cited by
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Reaction-based BODIPY probes for selective bio-imaging
Kolemen, S., & Akkaya, E. U. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.06.021 · Cited by 357
Towards a Chemiresistive Sensor-Integrated Electronic Nose: A Review
Chiu, S.-W., & Tang, K.-T. (2013) · Sensors · doi:10.3390/s131014214 · Cited by 242
Dieffenderfer, J., Goodell, H., Mills, S., McKnight, M., Yao, S., Lin, F., Beppler, E., Bent, B., Lee, B., Misra, V., et al. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2573286 · Cited by 212
Metadata
- Authors
- Arshak, K., Moore, E., Lyons, G. M., Harris, J., & Clifford, S.
- Venue
- Sensor Review
- Publisher
- Emerald
- Published
- 2004-06-01
- Volume
- 24
- Issue
- 2
- Pages
- 181-198
- ISSN
- 0260-2288 (ISSN-L)
- OpenAlex
- W2079296123
- Cited by
- 802
- References
- 34
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review of gas sensors employed in electronic nose applications. https://app.cochat.ai/papers/10.1108/02602280410525977
- The paper
- Arshak, K., Moore, E., Lyons, G. M., Harris, J., & Clifford, S. (2004). A review of gas sensors employed in electronic nose applications. Sensor Review. https://doi.org/10.1108/02602280410525977
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.