Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 176

The DOI matches its Crossref record.

Fused deposition modeling of patient‐specific polymethylmethacrylate implants

Espalin, David, Arcaute, Karina, Rodriguez, David, Medina, Francisco, Posner, Matthew, Wicker, Ryan·2010·Rapid Prototyping Journal

Abstract

Purpose: The purpose of this paper is to investigate the use of medical‐grade polymethylmethacrylate (PMMA) in fused deposition modeling (FDM) to fabricate porous customized freeform structures for several applications including craniofacial reconstruction and orthopaedic spacers. It also aims to examine the effects of different fabrication conditions on porosity and mechanical properties of PMMA samples. Design/methodology/approach: The building parameters and procedures to properly and consistently extrude PMMA filament in FDM for building 3D structures were determined. Two experiments were performed that examined the effects of different fabrication conditions, including tip wipe frequency, layer orientation, and air gap (AG) (or distance between filament edges) on the mechanical properties and porosity of the fabricated structures. The samples were characterized through optical micrographs, and measurements of weight and dimensions of the samples were used to calculate porosity. The yield strength, strain, and modulus of elasticity of the samples were determined through compressive testing. Findings: Results show that both the tip wipe frequency (one wipe every layer or one wipe every ten layers) and layer orientation (transverse or axial with respect to the applied compressive load) used to fabricate the scaffolds have effects on the mechanical properties and resulting porosity. The samples fabricate in the transverse orientation with the high tip wipe frequency have a larger compressive strength and modulus than the lower tip wipe frequency samples (compressive strength: 16±0.97 vs 13±0.71 MPa, modulus: 370±14 vs 313±29 MPa, for the high vs low tip wipe frequency, respectively). Also, the samples fabricated in the transverse orientation have a larger compressive strength and modulus than the ones fabricated in the axial orientation (compressive strength: 16±0.97 vs 13±0.83 MPa, modulus: 370±14 vs 281±22 MPa; for samples fabricated with one tip wipe per layer in the transverse and axial orientations, respectively). In general, the stiffness and yield strength decreased when the porosity increased (compressive strength: 12±0.71 to 7±0.95 MPa, Modulus: 248±10 to 165±16 MPa, for samples with a porosity ranging from 55 to 70 percent). As a demonstration, FDM is successfully used to fabricate patient‐specific, 3D PMMA implants with varying densities, including cranial defect repair and femur models. Originality/value: This paper demonstrates that customized, 3D, biocompatible PMMA structures with varying porosities can be designed and directly fabricated using FDM. By enabling the use of PMMA in FDM, medical implants such as custom craniofacial implants can be directly fabricated from medical imaging data improving the current state of PMMA use in medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1108/13552541011034825

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 176

Metadata

Authors
Espalin, D., Arcaute, K., Rodriguez, D., Medina, F., Posner, M., & Wicker, R.
Venue
Rapid Prototyping Journal
Publisher
Emerald
Published
2010-04-27
Volume
16
Issue
3
Pages
164-173
ISSN
1355-2546 (ISSN-L)
OpenAlex
W2012264942
Cited by
176
References
0
FWCI
14.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fused deposition modeling of patient‐specific polymethylmethacrylate implants. https://app.cochat.ai/papers/10.1108/13552541011034825
The paper
Espalin, D., Arcaute, K., Rodriguez, D., Medina, F., Posner, M., & Wicker, R. (2010). Fused deposition modeling of patient‐specific polymethylmethacrylate implants. Rapid Prototyping Journal. https://doi.org/10.1108/13552541011034825

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.