A flexible perforated microelectrode array for extended neural recordings
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A flexible and perforated 32-element planar microelectrode array has been fabricated and used to measure evoked potentials in brain slices. Electrodes are spaced 200 microns apart in a 4 x 8 array and are sandwiched between layers of insulating polyimide. The polyimide sandwich is lifted off its substrate, making it flexible so that it could shape to contoured tissues. Prior to lift off, holes are etched to expose recording sites 15 microns in diameter and to create perforations which allow increased circulation of artificial cerebrospinal fluid to the recording surface of the tissue and, hence, increased viability. Comparisons of evoked potentials measured over time showed an average increase of 10 h to the viability of the slice while using the perforated versus nonperforated arrays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177
Cited by
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
“Similar types of structures and processes have been previously reported [16], [17], [24], [27], [28].”
ResultA MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Maeda, E., Robinson, H., & Kawana, A. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-10-06834.1995 · Cited by 365
In vitro evaluation of the long-term stability of polyimide as a material for neural implants
Rubehn, B., & Stieglitz, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.053 · Cited by 242
Jung, D. R., Kapur, R., Adams, T., Giuliano, K. A., Mrksich, M., Craighead, H. G., & Taylor, D. L. (2001) · Critical Reviews in Biotechnology · doi:10.1080/20013891081700 · Cited by 171
Metadata
- Authors
- Boppart, S. A., Wheeler, B. C., & Wallace, C. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1992
- Volume
- 39
- Issue
- 1
- Pages
- 37-42
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2167268913
- Cited by
- 126
- References
- 1
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A flexible perforated microelectrode array for extended neural recordings. https://app.cochat.ai/papers/10.1109/10.108125
- The paper
- Boppart, S. A., Wheeler, B. C., & Wallace, C. S. (1992). A flexible perforated microelectrode array for extended neural recordings. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.108125
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.