Experimental tests of the cortical imaging technique-applications to the response to median nerve stimulation and the localization of epileptiform discharges
The DOI matches its Crossref record.
Abstract
In a previous paper a method for simulating the electric potentials on the surface of the brain was introduced. This method consisted of the construction of a layer of radially oriented current dipoles in a conducting sphere that simulated the head so that the voltages generated by the layer would take the values measured on the surface of the medium (the scalp). The harmonic potential function for this layer was then evaluated in the interior of the medium in an attempt to approximate the potentials that would be generated by the actual neural sources but which could not be observed without recourse to invasive recording techniques. This method, the cortical imaging technique (CIT), has been previously tested by applying it to artificially generated data where the "cortical surface" potentials were known and could be compared with CIT-generated potentials. In this paper the method is tested by applying it to the scalp-recorded potentials evoked by right median nerve stimulation, where direct cortical recordings are available for comparison, and to the scalp-recorded epileptiform discharges from two patients where the spike foci were well defined. The effects of varying the "noise ratio," an input parameter in CIT which allows one to account for noise in scalp-recorded data, is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A method to standardize a reference of scalp EEG recordings to a point at infinity
Yao, D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/305 · Cited by 576
High resolution EEG: 124-channel recording, spatial deblurring and MRI integration methods
Gevins, A., Le, J., Martin, N. K., Brickett, P., Desmond, J., & Reutter, B. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90050-7 · Cited by 246
“Unlike other methods which estimate cortical potentials or currents (e.g., Nicholas and Deloche 1976; Freeman 1980; Hill et al. 1988; Sidman et al. 1989, 1992), deblurring is a true "downward continuation" method in that the cortical potential distribution is derived without prior knowledge or…”
Multimodal Functional Neuroimaging: Integrating Functional MRI and EEG/MEG
He, B., & Liu, Z. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008233 · Cited by 171
“unit can also be defined as a current monopole [48], current multipole [49], or extracellular potential [50]–[58].”
BackgroundIntegration of EEG/MEG with MRI and fMRI
Liu, Z., Ding, L., & He, B. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1657787 · Cited by 102
“It has been shown that the cortical surface potentials imaged from either simulation or real data can provide much higher spatial resolution in observing the brain activity than scalp potentials [21], [22], [26]–[28].”
BackgroundAn alternative subspace approach to EEG dipole source localization
Xu, X.-L., Xu, B., & He, B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/2/010 · Cited by 73
Noninvasive cortical imaging of epileptiform activities from interictal spikes in pediatric patients
Lai, Y., Zhang, X., van Drongelen, W., Korhman, M., Hecox, K., Ni, Y., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.026 · Cited by 22
“…analysis, such as the dipole localization (He et al., 1987; Ebersole 1994), the distributed source analysis (Michel et al., 1999; Huppertz 2001b; Sidman et al., 1992; Ding et al, 2007a,b; Brodbeck et al., 2010) and the localization from EEG patterns (Ebersole et al., 1996; Ebersole 1997) in…”
Background
Metadata
- Authors
- Sidman, R. D., Vincent, D. J., Smith, D. B., & Lee, L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1992-05
- Volume
- 39
- Issue
- 5
- Pages
- 437-444
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2109396074
- Cited by
- 50
- References
- 0
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.