The DOI matches its Crossref record.
RF powering of millimeter- and submillimeter-sized neural prosthetic implants
Open accessAbstract
The size of the transducers for neural stimulation has shrunk steadily with application of thin-film techniques to electrode design. The feasibility is examined of designing millimeter- and submillimeter-sized power sources based on RF coupling that could be integrated into these implants to provide power without a tethering power cable. The coupling between a transmitter coil and receiver coil when the coil diameters are markedly different is analyzed, and for these circumstances, a simple Thevenin equivalent model is developed to describe the power transmission between the transmitter and receiver. The equivalent circuit developed gives insight into the way that coil diameters, frequency, and turns affect coupling between large and small coils. Several examples demonstrate that milliwatt range power sources can be implemented with millimeter- and submillimeter-diameter receivers.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 630
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Wireless Power Transfer in Loosely Coupled Links: Coil Misalignment Model
Fotopoulou, K., & Flynn, B. W. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2093534 · Cited by 391
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Metadata
- Authors
- Heetderks, W. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1988-05
- Volume
- 35
- Issue
- 5
- Pages
- 323-327
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2075593553
- Cited by
- 197
- References
- 0
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: RF powering of millimeter- and submillimeter-sized neural prosthetic implants. https://app.cochat.ai/papers/10.1109/10.1388
- The paper
- Heetderks, W. J. (1988). RF powering of millimeter- and submillimeter-sized neural prosthetic implants. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.1388
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.