Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 197

The DOI matches its Crossref record.

RF powering of millimeter- and submillimeter-sized neural prosthetic implants

Open access
Heetderks, W.J.·1988·IEEE Transactions on Biomedical Engineering

Abstract

The size of the transducers for neural stimulation has shrunk steadily with application of thin-film techniques to electrode design. The feasibility is examined of designing millimeter- and submillimeter-sized power sources based on RF coupling that could be integrated into these implants to provide power without a tethering power cable. The coupling between a transmitter coil and receiver coil when the coil diameters are markedly different is analyzed, and for these circumstances, a simple Thevenin equivalent model is developed to describe the power transmission between the transmitter and receiver. The equivalent circuit developed gives insight into the way that coil diameters, frequency, and turns affect coupling between large and small coils. Several examples demonstrate that milliwatt range power sources can be implemented with millimeter- and submillimeter-diameter receivers.>

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.1388

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 197

Metadata

Authors
Heetderks, W. J.
Venue
IEEE Transactions on Biomedical Engineering
Published
1988-05
Volume
35
Issue
5
Pages
323-327
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2075593553
Cited by
197
References
0
FWCI
0.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: RF powering of millimeter- and submillimeter-sized neural prosthetic implants. https://app.cochat.ai/papers/10.1109/10.1388
The paper
Heetderks, W. J. (1988). RF powering of millimeter- and submillimeter-sized neural prosthetic implants. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.1388

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.