Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
RF wireless interface enables remotely-powered implantable devices. Current studies in wireless power transmission into biological tissue tend to operate below 10 MHz due to tissue absorption loss, which results in large receive antennas. This paper examines the range of frequencies that will optimize the tradeoff between received power and tissue absorption. It first models biological tissue as a dispersive dielectric in a homogeneous medium and performs full-wave analysis to show that the optimal frequency is above 1 GHz for small receive coil and typical transmit-receive separations. Then, it includes the air-tissue interface and models human body as a planarly layered medium. The optimal frequency is shown to remain in the GHz-range. Finally, electromagnetic simulations are performed to include the effect of load impedance and look at the matched power gain. The optimal frequency is in the GHz-range for mm-sized transmit antenna and shifts to the sub-GHz range for cm-sized transmit antenna. The multiple orders of magnitude increase in the operating frequency enables dramatic miniaturization of implantable devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Theoretical studies have shown that energy transfer implemented with these characteristics can be 2-3 orders of magnitude more efficient than near-field systems (23,26).”
From Wireless power transfer to deep-tissue microimplants (2014) · cites this paper as [26]
Citations
Cites
Greiner, W. (1998) · Theoretical Physics · doi:10.1007/978-1-4612-0587-6 · Cited by 6,657
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 4×
“1 The real part begins to vary 1 The parameters in [23] are for the 4-term Cole-Cole model which is a variant of the Debye relaxation model.”
BackgroundMethodInfluentialWaves and Fields in Inhomogenous Media
Chew, W. C. (1999) · doi:10.1109/9780470547052 · Cited by 3,986
Classical Electrodynamics, 3rd ed .
Jackson, J. D., & Fox, R. F. (1999) · American Journal of Physics · doi:10.1119/1.19136 · Cited by 3,073
Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations
Kim, J., & Rahmat-Samii, Y. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832018 · Cited by 757
Design of Implantable Microstrip Antenna for Communication With Medical Implants
Soontornpipit, P., Furse, C. M., & Chung, Y. C. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.831976 · Cited by 472
Geometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 420
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Research works printed but not linked: 4
- donaldson, 1986, frequency-hopping in r.f. energy-transfer links, Electron Wireless World, 24
- galbraith, 1984, An implantable multichannel neural stimulator
- schuder, 1961, high-level electromagnetic energy transfer through a closed chest wall, IRE Int Conv Record, 9, 119
- 0, IE3D Version 12 2
Cited by
Shannon meets Tesla: Wireless information and power transfer
Grover, P., & Sahai, A. (2010) · 2010 IEEE International Symposium on Information Theory · doi:10.1109/isit.2010.5513714 · Cited by 1,033
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
“Theoretical studies have shown that energy transfer implemented with these characteristics can be 2–3 orders of magnitude more efficient than near-field systems (23, 26).”
BackgroundSelf-citationWireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
“on the dielectric properties of human tissues [107] is derived in [38].”
BackgroundMethodWireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
“However, reports of proper link modeling and characterization of the effects of ultrasound wave inside the human body are scarce compared to the EM WPT techniques [157,208].”
BackgroundMethod
Metadata
- Authors
- Poon, A. S. Y., O'Driscoll, S., & Meng, T. H.
- Affiliations
- Stanford University (US)
- ORCID
- Poon, Ada S Y
- Venue
- IEEE Transactions on Antennas and Propagation
- Published
- 2010-05
- Volume
- 58
- Issue
- 5
- Pages
- 1739-1750
- ISSN
- 0018-926X (ISSN-L)
- 1558-2221
- OpenAlex
- W2110545851
- Semantic Scholar
- e6a37dc9b793041a01befbefb870dde9882038d3
- Cited by
- 469
- References
- 25
- Citations by year
- 2026: 7 · 2025: 25 · 2024: 32 · 2023: 31 · 2022: 30 · 2021: 42 · 2020: 23 · 2019: 38 · 2018: 27 · 2017: 36 · 2016: 34 · 2015: 32 · 2014: 33 · 2013: 31 · 2012: 29
- FWCI
- 19.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Antennas and Propagation (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Energy Harvesting in Wireless Networks
- Keywords
- wireless power transfer, biomedical implants, optimal operating frequency, air-tissue interface, load impedance matching, RF power transmission
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue. https://app.cochat.ai/papers/10.1109/tap.2010.2044310
- The paper
- Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010). Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue. IEEE Transactions on Antennas and Propagation. https://doi.org/10.1109/tap.2010.2044310
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.