Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 479

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex

Edell, D.J., Toi, V.V., McNeil, V.M., Clark, L.D.·1992·IEEE Transactions on Biomedical Engineering

Abstract

Insertable microelectrode arrays can be used to activate neurons or to sense neural signals for use in prosthetics. The relationship of the microelectrodes to the neurons is determined by random alignment and by biocompatibility. Issues that determine the biocompatibility of insertable microelectrode arrays were investigated. Arrays were implanted into the cortex of rabbit brain and fixed to the skull. Following six-month survival, neuron density as a function of distance from the shafts of the arrays was measured to assess destruction of neurons. Results from a limited number of tests indicated that there was minimal tissue response along the sides of the shafts when shafts were well sharpened, had sufficiently small tip angles, and were clean. Tissue was usually more reactive at the tips of the shafts. It was concluded that silicon microshafts of appropriate shaft and tip design were biocompatible along the sides of the shaft, but that relatively severe reactions could be anticipated at the tips. Recording or stimulation sites should be located away from the tips on the sides of the shafts for better coupling with individual neurons. Measurement of neuron density as a function of distance from the shafts was a sensitive and quantitative technique for assessing biocompatibility. Additional measures such as glial density as a function of distance from the shafts, and incidence of microhematoma formation were proposed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.141202

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 479

Metadata

Authors
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D.
Venue
IEEE Transactions on Biomedical Engineering
Published
1992-06
Volume
39
Issue
6
Pages
635-643
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2143287453
Cited by
479
References
2
FWCI
0.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex. https://app.cochat.ai/papers/10.1109/10.141202
The paper
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992). Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.141202

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.