The DOI matches its Crossref record.
A New Instrument for Continuous Measurement of Tissue Blood Flow by Light Beating Spectroscopy
Abstract
A new instrument for measurement of regional tissue blood flow based on the laser Doppler principle is reported. The theoretical background of light beating spectroscopy is discussed and a detection technique which makes possible the suppression of the adverse effects of laser-mode interference and wide-band beam amplitude noise is described. Instead of using a single square-law photodetector a differential detector technique is introduced that reduces common-mode noise to a negligible level, without influencing the blood flow related signal. The new instrument has proved to be highly stable and sensitive. Continuous recordings of tissue blood flow can be performed in the laboratory as well as at the bedside.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Laser Doppler perfusion imaging by dynamic light scattering
Wardell, K., Jakobsson, A., & Nilsson, G. E. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.222322 · Cited by 435
Self-citationFerrell, W. R., Ramsay, J. E., Brooks, N., Lockhart, J. C., Dickson, S., McNeece, G. M., Greer, I. A., & Sattar, N. (2002) · Journal of Vascular Research · doi:10.1159/000064515 · Cited by 76
Photoplethysmography: Part 1 Comparison with laser Doppler flowmetry
Lindberg, L. G., Tamura, T., & Öberg, P. Å. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446294 · Cited by 46
Shibahara, N., Matsuda, H., Umeno, K., Shimada, Y., Itoh, T., & Terasawa, K. (1996) · Journal of the Autonomic Nervous System · doi:10.1016/s0165-1838(96)00065-3 · Cited by 28
Metadata
- Authors
- Nilsson, G. E., Tenland, T., & Oberg, P. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1980-01
- Volume
- BME-27
- Issue
- 1
- Pages
- 12-19
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1985176577
- Cited by
- 591
- References
- 0
- FWCI
- 8.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Instrument for Continuous Measurement of Tissue Blood Flow by Light Beating Spectroscopy. https://app.cochat.ai/papers/10.1109/tbme.1980.326686
- The paper
- Nilsson, G. E., Tenland, T., & Oberg, P. A. (1980). A New Instrument for Continuous Measurement of Tissue Blood Flow by Light Beating Spectroscopy. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1980.326686
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.