Method to reduce blur distortion from EEG's using a realistic head model
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A mathematical procedure, which we call "Deblurring," was developed to reduce spatial blur distortion of scalp-recorded brain potentials due to transmission through the skull and other tissues. Deblurring estimates potentials at the superficial cerebral cortical surface from EEG's recorded at the scalp using a finite element model of each subject's scalp, skull and cortical surface constructed from their magnetic resonance images (MRI's). Simulations indicate that Deblurring is numerically stable, while a comparison of deblurred data with a direct cortical recording from a neurosurgery patient suggests that the procedure is valid. Application of Deblurring to somatosensory evoked potential data recorded at 124 scalp sites suggests that the method produces a dramatic improvement in spatial detail, and merits further development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Helmholtz, H. (1853) · Annalen der Physik · doi:10.1002/andp.18531650603 · Cited by 989
Finite-element model of the human head: scalp potentials due to dipole sources
Yan, Y., Nunez, P. L., & Hart, R. T. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442317 · Cited by 208
Cited by
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798
Gevins, A. (1997) · Cerebral Cortex · doi:10.1093/cercor/7.4.374 · Cited by 1,623
Self-citationNunez, P. L., Srinivasan, R., Westdorp, A. F., Wijesinghe, R. S., Tucker, D. M., Silberstein, R. B., & Cadusch, P. J. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00066-7 · Cited by 1,225
Nunez, P. L., Wingeier, B. M., & Silberstein, R. B. (2001) · Human Brain Mapping · doi:10.1002/hbm.1030 · Cited by 510
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494
“Finite element methods (FEM’s) are capable of modeling nonhomogeneous and anisotropic conductivities within each tissue and therefore will be dependent upon accurate conductivity values for the whole head, but present FEM models are limited by the paucity of conductivity data [10].”
Background
Metadata
- Authors
- Le, J., & Gevins, A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1993-06
- Volume
- 40
- Issue
- 6
- Pages
- 517-528
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2023910133
- Cited by
- 145
- References
- 2
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Method to reduce blur distortion from EEG's using a realistic head model. https://app.cochat.ai/papers/10.1109/10.237671
- The paper
- Le, J., & Gevins, A. (1993). Method to reduce blur distortion from EEG's using a realistic head model. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.237671
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.