Method to reduce blur distortion from EEG's using a realistic head model
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A mathematical procedure, which we call "Deblurring," was developed to reduce spatial blur distortion of scalp-recorded brain potentials due to transmission through the skull and other tissues. Deblurring estimates potentials at the superficial cerebral cortical surface from EEG's recorded at the scalp using a finite element model of each subject's scalp, skull and cortical surface constructed from their magnetic resonance images (MRI's). Simulations indicate that Deblurring is numerically stable, while a comparison of deblurred data with a direct cortical recording from a neurosurgery patient suggests that the procedure is valid. Application of Deblurring to somatosensory evoked potential data recorded at 124 scalp sites suggests that the method produces a dramatic improvement in spatial detail, and merits further development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Helmholtz, H. (1853) · Annalen der Physik · doi:10.1002/andp.18531650603 · Cited by 989
Finite-element model of the human head: scalp potentials due to dipole sources
Yan, Y., Nunez, P. L., & Hart, R. T. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442317 · Cited by 208
Cited by
Measuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798
Gevins, A. (1997) · Cerebral Cortex · doi:10.1093/cercor/7.4.374 · Cited by 1,623
Self-citationNunez, P. L., Srinivasan, R., Westdorp, A. F., Wijesinghe, R. S., Tucker, D. M., Silberstein, R. B., & Cadusch, P. J. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00066-7 · Cited by 1,225
Nunez, P. L., Wingeier, B. M., & Silberstein, R. B. (2001) · Human Brain Mapping · doi:10.1002/hbm.1030 · Cited by 510
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494
“Finite element methods (FEM’s) are capable of modeling nonhomogeneous and anisotropic conductivities within each tissue and therefore will be dependent upon accurate conductivity values for the whole head, but present FEM models are limited by the paucity of conductivity data [10].”
BackgroundToward a quantitative description of large-scale neocortical dynamic function and EEG
Nunez, P. L. (2000) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00003253 · Cited by 467
Nunez, P. L., Silberstein, R. B., Cadusch, P. J., Wijesinghe, R. S., Westdorp, A. F., & Srinivasan, R. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90112-0 · Cited by 421
EEG coherency II: experimental comparisons of multiple measures
Nunez, P. L., Silberstein, R. B., Shi, Z., Carpenter, M. R., Srinivasan, R., Tucker, D. M., Doran, S. M., Cadusch, P. J., & Wijesinghe, R. S. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00043-1 · Cited by 316
Nunez, P. L., & Silberstein, R. B. (2000) · Brain Topography · doi:10.1023/a:1026683200895 · Cited by 307
Tenke, C. E., & Kayser, J. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.06.005 · Cited by 273
Large-Scale Gamma-Band Phase Synchronization and Selective Attention
Doesburg, S. M., Roggeveen, A. B., Kitajo, K., & Ward, L. M. (2008) · Cerebral Cortex · doi:10.1093/cercor/bhm073 · Cited by 261
High resolution EEG: 124-channel recording, spatial deblurring and MRI integration methods
Gevins, A., Le, J., Martin, N. K., Brickett, P., Desmond, J., & Reutter, B. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90050-7 · Cited by 246
“…of the finite element method, the potentials measured at the electrode positions are interpolated onto vertices of tetrahedrons defining the scalp model using a local spline-like interpolation function which is active near the area of interest and dormant outside this region (Le and Gevins 1993).”
InfluentialSelf-citationFaria, P., Hallett, M., & Miranda, P. C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066017 · Cited by 243
“This blurring effect of the skull is well documented in the EEG literature (see, e.g., Le and Gevins (1993)).”
Babiloni, F., Babiloni, C., Carducci, F., Fattorini, L., Onorati, P., & Urbano, A. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(96)00284-2 · Cited by 231
High resolution evoked potential imaging of the cortical dynamics of human working memory
Gevins, A., Smith, M. E., Le, J., Leong, H., Bennett, J., Martin, N., McEvoy, L., Du, R., & Whitfield, S. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(96)00288-x · Cited by 225
Self-citationMultimodal Functional Neuroimaging: Integrating Functional MRI and EEG/MEG
He, B., & Liu, Z. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008233 · Cited by 171
Mapping cognitive brain function with modern high-resolution electroencephalography
Gevins, A., Leong, H., Smith, M. E., Le, J., & Du, R. (1995) · Trends in Neurosciences · doi:10.1016/0166-2236(95)94489-r · Cited by 164
Self-citationIntegration of EEG/MEG with MRI and fMRI
Liu, Z., Ding, L., & He, B. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1657787 · Cited by 102
“Subsequently, boundary element method (BEM) [13,15–16] or finite element method (FEM) [17–20] is commonly employed to implement the numerical forward calculation.”
MethodElectrophysiological Mapping and Neuroimaging
He, B., & Ding, L. (2013) · Neural Engineering · doi:10.1007/978-1-4614-5227-0_12 · Cited by 26
Metadata
- Authors
- Le, J., & Gevins, A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1993-06
- Volume
- 40
- Issue
- 6
- Pages
- 517-528
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2023910133
- Cited by
- 145
- References
- 2
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.