Optimal detection, classification, and superposition resolution in neural waveform recordings
The DOI matches its Crossref record.
Abstract
The effects of noise autocorrelation on neural waveform recognition (detection, classification, and superposition resolution) are investigated in this study using microelectrode recordings from the cortex of a monkey. Optimal waveform recognition is accomplished by passing the data through a whitening filter before matched filtering for detection or template matching for classification and superposition resolution. Template matching without whitening requires about 40% higher signal-to-noise ratio than template matching with whitening for comparable classification and superposition resolution. The comparable difference for detection is 15%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oscillatory coupling of hippocampal pyramidal cells and interneurons in the behaving rat
Csicsvari, J., Hirase, H., Czurkó, A., Mamiya, A., & Buzsáki, G. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-01-00274.1999 · Cited by 966
“The power (root mean square) of the filtered signal was computed in a sliding window (0.2 msec) for spike detection (Bankman et al., 1993).”
MethodInfluentialMaynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Reliability and State Dependence of Pyramidal Cell–Interneuron Synapses in the Hippocampus
Csicsvari, J., Hirase, H., Czurko, A., & Buzsáki, G. (1998) · Neuron · doi:10.1016/s0896-6273(00)80525-5 · Cited by 606
The extraction of neural strategies from the surface EMG: an update
Farina, D., Merletti, R., & Enoka, R. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00162.2014 · Cited by 589
Spike Detection Using the Continuous Wavelet Transform
Nenadic, Z., & Burdick, J. W. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839800 · Cited by 375
Rutishauser, U., Schuman, E. M., & Mamelak, A. N. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.12.033 · Cited by 343
Sustained activation of hippocampal pyramidal cells by ‘space clamping’ in a running wheel
Czurkó, A., Hirase, H., Csicsvari, J., & Buzsáki, G. (1999) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.1999.00446.x · Cited by 325
Evaluation of Spike-Detection Algorithms for a Brain-Machine Interface Application
Obeid, I., & Wolf, P. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826683 · Cited by 262
A 100-channel system for real time detection and storage of extracellular spike waveforms
Guillory, K. S., & Normann, R. A. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00076-x · Cited by 180
Micera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Metadata
- Authors
- Bankman, I. N., Johnson, K. O., & Schneider, W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1993
- Volume
- 40
- Issue
- 8
- Pages
- 836-841
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2121835671
- Cited by
- 108
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.