An adaptive plasma glucose controller based on a nonlinear insulin/glucose model
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The design of plasma glucose controllers traditionally relies on linear approaches. The implementation of an appropriate nonlinear model of the insulin/glucose regulatory system into an adaptive controller should predict the insulin-dependent glucose removal more reliably and hence provide better control over a wide spectrum of insulin signals. A discretized form of the model leads to a two-step procedure. First, the measured plasma glucose levels associated with the exogenous glucose infusion rates are used in the estimation of the past removal rates which, in turn, can be expressed as a weighted sum of past insulin inputs and previous values of the removal rate. Parameters of the sum are adjusted on-line by a recursive method of estimation which features a prefiltering of data to account for a corrupting coloured process noise. The same equation is in turn used to predict the time course of the insulin-dependent fractional rate of glucose removal. The performance of the controller, tested in vivo in three pigs, is presented for various intravenous or subcutaneous rapid injections and staircase infusions of insulin. Plasma glucose is maintained at an average level of 99.9 +/- 8.7% of the target value (% set point +/- coefficient of variation). The controller reacts promptly to large and rapid variations in insulin action. Although control improves with the number of glucose measurements, the prediction of glucose removal allows for some flexibility in the monitoring of the plasma glucose. Sampling frequency varied from a 2 min interval during transient periods to 7 min as steady states were reached.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874
Experimental validation of measurements of glucose turnover in nonsteady state.
Radziuk, J., Norwich, K. H., & Vranic, M. (1978) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1978.234.1.e84 · Cited by 277 · cited 1×
“The constant parameters {a,} in equations (1) to (5) cannot be completely separated from the estimates of { A , } and {I?&}.”
BackgroundSelf-citationInsulin Control of Glucose Metabolism in Man
Insel, P. A., Liljenquist, J. E., Tobin, J. D., Sherwin, R. S., Watkins, P., Andres, R., & Berman, M. (1975) · Journal of Clinical Investigation · doi:10.1172/jci108006 · Cited by 244
Cited by
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
“…infused insulin (Cobelli and Mari 1985) and only with the availability of short-acting insulin (Howey et al 1994) could the next generation of control algorithms have been developed (Brunetti et al 1993, Candas and Radziuk 1994, Shichiri et al 1998, Shimoda et al 1997, Trajanoski and Wach 1998).”
BackgroundMakroglou, A., Li, J., & Kuang, Y. (2006) · Applied Numerical Mathematics · doi:10.1016/j.apnum.2005.04.023 · Cited by 367
“Faria (2003) [35]— optimal control for a utility function involving a medical treatment, diet and exercise routines, Candas and Radziuk (1994) [22]—adaptive plasma glucose controller, Ruiz-Velázquez et al.”
BackgroundClosed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
El-Khatib, F. H., Jiang, J., & Damiano, E. R. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100208 · Cited by 99
Metadata
- Authors
- Candas, B., & Radziuk, J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1994
- Volume
- 41
- Issue
- 2
- Pages
- 116-124
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2141248178
- Cited by
- 49
- References
- 3
- FWCI
- 0.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An adaptive plasma glucose controller based on a nonlinear insulin/glucose model. https://app.cochat.ai/papers/10.1109/10.284922
- The paper
- Candas, B., & Radziuk, J. (1994). An adaptive plasma glucose controller based on a nonlinear insulin/glucose model. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.284922
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.