Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Adaptive Closed-Loop Control Provides Blood-Glucose Regulation Using Dual Subcutaneous Insulin and Glucagon Infusion in Diabetic Swine

Open access
El-Khatib, Firas H., Jiang, John, Damiano, Edward R. · 2007 · Journal of Diabetes Science and Technology

Abstract

Background: In order to stave off deleterious complications of the disease, the ultimate task for people with diabetes is to maintain their blood glucose in euglycemic range. Despite technological advancements, conventional open-loop therapy often results in prolonged hyperglycemia and episodic hypoglycemia, in addition to necessitating carbohydrate counting, frequent glucose monitoring, and drug administration. The logical conclusion in the evolution of exogenous insulin therapy is to develop an automated closed-loop control system. Methods: Eleven closed-loop control experiments were conducted in four anesthetized diabetic pigs, with carbohydrate loads simulated by intravenous glucose administration through ear-vein catheters. Type 1 diabetes-like pathology was induced using intravenous administration of cytotoxin streptozotocin. The augmented model-predictive control algorithm accounts for the accumulation of subcutaneous insulin, which is critical in avoiding excessive insulin dosing. Results: Control results consistently showed successful blood-glucose regulation to euglycemic range within 80–120 minutes after intravenous glucose loads, with no incidence of hypoglycemia. This is consistent with a negative oral glucose tolerance test for diabetes and is the optimal postprandial regulation that can be achieved with subcutaneous insulin administration. Results also demonstrated the potency of subcutaneous glucagon in staving off episodic hypoglycemia and revealed efficacy of the control algorithm in coping with a twofold variation in subject weights, while simultaneously overlooking erratic blood-glucose fluctuations. Conclusions: Using an automated adaptive glucose-control system, we show successful blood-glucose regulation in vivo and establish, definitively, the plausibility and practicality of closed-loop blood-glucose control using subcutaneous insulin and glucagon infusion in type 1 diabetes. The control system strikes an intricate balance between tight blood-glucose control and optimal drug consumption, while simultaneously maintaining emphasis on simplicity and reliability.

Overview

Integrity signals

Registry

Crossref · 10.1177/193229680700100208

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 39 references

Research works printed but not linked: 9

  1. Eiselein L, 2004, LAR J., 45, 231
  2. Reckless J, 2004, Diabetes Primary Care., 6, 134
  3. Clemens AH, 1979, Med Prog Technol., 6, 91
  4. Femat R, 1999, Proc IEEE Intl Conf Control App., 1, 1290
  5. El-Khatib FH, 2005, System identification and adaptive closed-loop glucose control in a type 1 diabetic swine model [dissertation]
  6. 10.1016/0005-1098(87)90087-2 · DOI · Paper page
  7. 10.1016/0005-1098(89)90002-2 · DOI · Paper page
  8. Noble SL, 1998, Am Fam Physician., 57, 279
  9. 10.1089/dia.2006.0006 · DOI

Cited by

See all 103

Metadata

Authors
El-Khatib, F. H., Jiang, J., & Damiano, E. R.
Affiliations
Boston University (US)
Corresponding author
Damiano, Edward R.
Venue
Journal of Diabetes Science and Technology
Published
2007-03
Volume
1
Issue
2
Pages
181-192
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2101160802
Cited by
99
References
39
Citations by year
2025: 2 · 2024: 2 · 2022: 1 · 2021: 4 · 2020: 4 · 2019: 6 · 2018: 10 · 2017: 6 · 2016: 3 · 2015: 8 · 2014: 7 · 2013: 7 · 2012: 9
FWCI
5.60
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Optimization
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
Keywords
closed-loop glucose control, type 1 diabetes, subcutaneous insulin infusion, model predictive control, adaptive control, blood glucose regulation, streptozotocin-induced diabetes, porcine model, hypoglycemia prevention, postprandial blood glucose

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptive Closed-Loop Control Provides Blood-Glucose Regulation Using Dual Subcutaneous Insulin and Glucagon Infusion in Diabetic Swine. https://app.cochat.ai/papers/10.1177/193229680700100208
The paper
El-Khatib, F. H., Jiang, J., & Damiano, E. R. (2007). Adaptive Closed-Loop Control Provides Blood-Glucose Regulation Using Dual Subcutaneous Insulin and Glucagon Infusion in Diabetic Swine. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680700100208

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.