Variations in optical absorption spectra of adult and fetal haemoglobins and its effect on pulse oximetry
The DOI matches its Crossref record.
Abstract
One of the concerns clinicians have relates to the interpretation of noninvasive pulse oximeters in newborns since at birth high levels of fetal hemoglobin (HbF) is present in the blood. Accurate in vivo studies of pulse oximeters in infants with predominantly HbF cannot be easily performed. Therefore, the objective of this in vitro study was to determine whether the presence of high levels of HbF in the blood can significantly affect the accuracy of noninvasive pulse oximeters. It is evident from our results that there is no perceptible difference in the 650-1000 nm wavelength region, which is commonly used in pulse oximetry, between the optical absorption spectra of hemolyzed whole adult and fetal blood. Our observations are in good agreement with in vivo studies published by other investigators showing considerable correlations between SpO2 measured by a pulse oximeter and SaO2 values analyzed in vitro by an IL 282 CO-Oximeter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zijlstra, W. G., Buursma, A., & Meeuwsen-van der Roest, W. P. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.9.1633 · Cited by 665
Pulse oximetry: fundamentals and technology update
Nitzan, M., Romem, A., & Koppel, R. (2014) · Medical Devices: Evidence and Research · doi:10.2147/mder.s47319 · Cited by 438
The effect of varying LED intensity on pulse oximeter accuracy
De Kock, J. P., Reynolds, K. J., Tarassenko, L., & Moyles, J. T. B. (1991) · Journal of Medical Engineering & Technology · doi:10.3109/03091909109016208 · Cited by 16
Haxha, S., Nwibor, C., Ali, M., Sakel, M., Saunders, K., Dyo, V., & Nabakooza, S. (2024) · Sensors · doi:10.3390/s24113301 · Cited by 12
“Mapping of SaO 2 values is performed using the following expression [49]: where K 2 is a multiple of the ratio of red to infrared light deflected by the body tissues.”
BackgroundMethod
Metadata
- Authors
- Mendelson, Y., & Kent, J. C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1989
- Volume
- 36
- Issue
- 8
- Pages
- 844-848
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1969725765
- Cited by
- 60
- References
- 0
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.