Cited by 16Non-Invasive Vital Sign MonitoringOptical Imaging and Spectroscopy TechniquesAnalytical Chemistry and Sensors

The effect of varying LED intensity on pulse oximeter accuracy

De Kock, J. P., Reynolds, K. J., Tarassenko, L., Moyles, J. T. B.·1991·Journal of Medical Engineering & Technology

Abstract

Most pulse oximeters automatically alter the intensity of their light-emitting diodes (LEDs) according to the absorption of the finger, toe or earlobe to which they are attached. This paper investigates the effect of changing LED intensity on pulse oximeter accuracy. Our results show that the peak wavelength of a red LED typically increases by 8 nm as its intensity is increased ten-fold. To determine whether this shift introduces a significant error, a simple theoretical model based on the Beer-Lambert law is used. The model predicts that a 10:1 change in LED intensity results in a 2.5% error at 50% arterial oxygen saturation (SpO2). At high saturations (SpO2 greater than or equal to 85%) the model predicts little loss of accuracy and thus any effect due to changes in LED intensity will be apparent only at low saturations.

Integrity signals

Registry

Crossref · 10.3109/03091909109016208

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
De Kock, J. P., Reynolds, K. J., Tarassenko, L., & Moyles, J. T. B.
Affiliations
  • John Radcliffe Hospital (GB)
  • University of Oxford (GB)
  • Milton Keynes Hospital (GB)
Venue
Journal of Medical Engineering & Technology
Published
1991-01
Volume
15
Issue
3
Pages
111-115
ISSN
  • 0309-1902 (ISSN-L)
  • 1464-522X
OpenAlex
W2093531986
Cited by
16
References
10
Citations by year
2026: 1 · 2025: 2 · 2023: 2 · 2022: 1 · 2018: 1 · 2012: 1
FWCI
1.28
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Medical Engineering & Technology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
Keywords
pulse oximetry, oxygen saturation measurement, red LED, peak wavelength shift, Beer-Lambert law, measurement error, arterial oxygen saturation
MeSH terms
Equipment Design, Hemoglobins, Humans, Hydrogen-Ion Concentration, Models, Theoretical, Oximetry, Oxygen, Predictive Value of Tests, Reference Values

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review