The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Abstract
Silicon micromachining and thin-film technology have been employed to fabricate iridium stimulating arrays which can be used to excite discrete volumes of the central nervous system. Silicon multichannel probes with thicknesses ranging from 1 to 40 microns and arbitrary two-dimensional shapes can be fabricated using a high-yield, circuit-compatible process. Iridium stimulating sites are shown to have similar characteristics to iridium wire electrodes. Accelerated pulse testing with over 8 million 100 microA biphasic current pulses on 8000 microns 2 sites has demonstrated the long-term stability of iridium and activated iridium sites. In vivo tests have been performed in the central auditory pathways to demonstrate neural activation using the devices. These tests show a selective activation both as a function of site separation and site size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Self-citation
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationLudwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Metadata
- Authors
- Anderson, D. J., Najafi, K., Tanghe, S. J., Evans, D. A., Levy, K. L., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1989-07
- Volume
- 36
- Issue
- 7
- Pages
- 693-704
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2099393975
- Cited by
- 229
- References
- 2
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Batch fabricated thin-film electrodes for stimulation of the central auditory system. https://app.cochat.ai/papers/10.1109/10.32101
- The paper
- Anderson, D. J., Najafi, K., Tanghe, S. J., Evans, D. A., Levy, K. L., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989). Batch fabricated thin-film electrodes for stimulation of the central auditory system. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.32101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.