CoChat

EMG pattern analysis for patient-responsive control of FES in paraplegics for walker-supported walking

Graupe, D. · 1989 · IEEE Transactions on Biomedical Engineering
Cited by 96

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

This paper describes and discusses the employment of EMG pattern analysis to provide upper-motor-neuron paraplegics with patient-responsive control of FES (functional electrical stimulation) for the purpose of walker-supported walking. The system described employs above-lesion surface EMG signals to activate standing and walking functions in a patient-responsive manner. This system has been experimentally applied to paraplegics at Michael Reese Hospital and Medical Center in Chicago since early 1982. Below-lesion response-EMG control from the stimulated sites has been added in 1987 to regulate stimuli levels in the face of fatigue. Although transcutaneous FES alone is being employed, the system is applicable in principle also to implantable FES systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.32103

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 96

Metadata

Authors
Graupe, D.
Venue
IEEE Transactions on Biomedical Engineering
Published
1989-07
Volume
36
Issue
7
Pages
711-719
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2003434394
Cited by
96
References
2
FWCI
1.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: EMG pattern analysis for patient-responsive control of FES in paraplegics for walker-supported walking. https://app.cochat.ai/papers/10.1109/10.32103
The paper
Graupe, D. (1989). EMG pattern analysis for patient-responsive control of FES in paraplegics for walker-supported walking. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.32103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.