CoChat

A technique for measurement of the extent of spatial organization of atrial activation during atrial fibrillation in the intact human heart

Botteron, G.W., Smith, J.M. · 1995 · IEEE Transactions on Biomedical Engineering
Cited by 221

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Atrial fibrillation (AF) is a common clinical problem, associated with considerable morbidity and mortality, for which effective management strategies have yet to be devised. The absence of objective measures to guide selection of antiarrhythmic drug therapy for maintenance of sinus rhythm leaves only clinical endpoints (either beneficial or detrimental) for assessment of drug action, with occasional catastrophic consequences. As part of an attempt to provide an objective framework for the assessment of antiarrhythmic drug action on the electrophysiologic determinants of atrial fibrillation, we have developed a measure of the spatial organization of atrial activation processes during atrial fibrillation. By recording activation sequences at multiple equally spaced locations on the endocardial surface of the atria during atrial fibrillation in humans and determining the degree of correlation between these activation sequences as a function of distance, we have been able to construct spatial correlation functions for atrial activation. We have found that atrial activation remains well-correlated, independent of distance during normal sinus rhythm and atrial flutter. During atrial fibrillation, correlation decays monotonically with distance and the space-constant for this decay may be used to describe the relative spatial organization of atrial fibrillation. We provide examples of the impact of antiarrhythmic agents on the space-constant and suggest that assessment of the relative spatial organization of atrial activation using this methodology may potentially provide an objective framework to guide therapy in patients with AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.387197

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Metadata

Authors
Botteron, G. W., & Smith, J. M.
Venue
IEEE Transactions on Biomedical Engineering
Published
1995-06
Volume
42
Issue
6
Pages
579-586
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2166966593
Cited by
221
References
14
FWCI
2.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A technique for measurement of the extent of spatial organization of atrial activation during atrial fibrillation in the intact human heart. https://app.cochat.ai/papers/10.1109/10.387197
The paper
Botteron, G. W., & Smith, J. M. (1995). A technique for measurement of the extent of spatial organization of atrial activation during atrial fibrillation in the intact human heart. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.387197

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.