CoChat

A 3-D impedance method to calculate power deposition in biological bodies subjected to time varying magnetic fields

Orcutt, N., Gandhi, O.P. · 1988 · IEEE Transactions on Biomedical Engineering
Cited by 181

The DOI matches its Crossref record.

Abstract

A previously described two-dimensional impedance method (ibid., vol.31, p.644-51, 1984) for modeling the response of biological bodies exposed to time-varying electromagnetic fields has been extended to three dimensions. This method is useful at those frequencies where the quasistatic approximation is valid and calculates the fields, current densities, and power depositions in the bodies. Solutions using this method for homogeneous spheres in plane waves are presented and compared to the analytic solutions for the same configuration. Solutions for a man exposed to a uniform radio-frequency magnetic field at 30 MHz, are presented, as well as for a man exposed to either circularly or linearly polarized magnetic fields at 63 MHz, uniform within a portion of his body and linearly decreasing outside of that portion, which approximates the exposure in some nuclear-magnetic-resonance imaging devices.>

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.4590

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Orcutt, N., & Gandhi, O. P.
Venue
IEEE Transactions on Biomedical Engineering
Published
1988-08
Volume
35
Issue
8
Pages
577-583
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2017126038
Cited by
181
References
0
FWCI
2.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.