Abstract

The three‐dimensional impedance method was used to estimate specific absorption rate (SAR) in a human‐torso model during exposure to the time‐varying and static magnetic fields used in magnetic resonance imaging (MRI). Analytical data for discrete tissues as well as the entire torso are presented. Generalized equations were derived that enable calculation of whole‐torso SAR over a broad range of conditions. In addition, the impedance method can generate data about internal distributions of SAR, which are needed to predict critical organs that might undergo excessive elevations of temperature. Fair to good agreement was found between impedance‐method SAR and those predicted by simple phenomenological models.

Overview

Integrity signals

Registry

Crossref · 10.1002/bem.2250110203

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 13 references

Research works printed but not linked: 9

  1. Budinger TF, 1988, Medical Magnetic Resonance: A Primer–1988, 327
  2. Grandolfo M, 1987, Safety Assessment of NMR Clinical Equipment, 50
  3. Hutchinson JMS, 1988, The physics of NMR spectroscopy in biology and medicine
  4. IRPA(in press): Protection of the patient undergoing magnetic resonance examinations. Health Phys.
  5. Lee SY, 1985, Fourth Annual Meeting of the Society of Magnetic Resonance in Medicine, 1011
  6. Meyer W, 1984, Third Annual Meeting of the Society of Magnetic Resonance in Medicine, 523
  7. Repacholi MH, 1986, Biological Effects of Static and Extremely Low Frequency Magnetic Fields, 171
  8. VollmannW KuhnMH(1985): Throughput limitations in clinical MR imaging due to RF heating. In Hopf MA Bydder GM (eds): “Magnetic Resonance Imaging and Spectroscopy. Proceedings of the First Congress of the European Society of Magnetic Resonance in Medicine and Biology Geneva October 5–6 1984.” Geneva: European Society of Magnetic Resonance in Medicine and Biology pp292–298.
  9. Wehrli FW, 1988, Medical Magnetic Resonance: A Primer—1988, 61

Metadata

Authors
Grandolfo, M., Vecchia, P., & Gandhi, O. P.
Affiliations
  • Istituto Superiore di Sanità (IT)
  • Istituto Nazionale di Fisica Nucleare (IT)
  • University of Utah (US)
Corresponding author
Grandolfo, Martino
Venue
Bioelectromagnetics
Publisher
Wiley
Published
1990-01
Volume
11
Issue
2
Pages
117-128
ISSN
  • 0197-8462 (ISSN-L)
  • 1521-186X
OpenAlex
W2017746474
Cited by
36
References
13
Citations by year
2022: 1 · 2021: 1 · 2020: 1 · 2018: 2 · 2017: 1 · 2015: 1 · 2013: 1 · 2012: 1
FWCI
1.79
Type
journal article
Language
en
Open access
closed
Locations
  • Bioelectromagnetics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Measurements
Keywords
magnetic resonance imaging, specific absorption rate, human torso model, SAR distribution, phenomenological model
MeSH terms
Electromagnetic Fields, Energy Transfer, Humans, Magnetic Resonance Imaging, Models, Structural

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic resonance imaging: Calculation of rates of energy absorption by a human‐torso model. https://app.cochat.ai/papers/10.1002/bem.2250110203
The paper
Grandolfo, M., Vecchia, P., & Gandhi, O. P. (1990). Magnetic resonance imaging: Calculation of rates of energy absorption by a human‐torso model. Bioelectromagnetics. https://doi.org/10.1002/bem.2250110203

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.