Skin impedance from 1 Hz to 1 MHz

Rosell, J., Colominas, J., Riu, P., Pallas-Areny, R., Webster, J.G.·1988·IEEE Transactions on Biomedical Engineering

Abstract

The impedance of skin coated with gel but otherwise unprepared was measured from 1 Hz to 1 MHz at ten sites on the thorax, leg, and forehead of ten subjects. For a 1-cm/sup 2/ area, the 1 Hz impedance varied from 10 k Omega to 1 M Omega , which suggests that the bipotential amplifier input impedance should be very high to avoid common-mode-to-differential-mode voltage conversion. The 1-MHz impedance was tightly clustered about 120 Omega . The 100-kHz impedance was about 220 Omega , which suggests that the variation in skin impedance can cause errors in two-electrode electrical impedance tomographs.>

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.4599

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 343

Metadata

Authors
Rosell, J., Colominas, J., Riu, P., Pallas-Areny, R., & Webster, J. G.
Venue
IEEE Transactions on Biomedical Engineering
Published
1988
Volume
35
Issue
8
Pages
649-651
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2115969310
Cited by
343
References
0
FWCI
3.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Skin impedance from 1 Hz to 1 MHz. https://app.cochat.ai/papers/10.1109/10.4599
The paper
Rosell, J., Colominas, J., Riu, P., Pallas-Areny, R., & Webster, J. G. (1988). Skin impedance from 1 Hz to 1 MHz. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.4599

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.