The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Bristle-sensors—low-cost flexible passive dry EEG electrodes for neurofeedback and BCI applications
Abstract
In this paper, we present a new, low-cost dry electrode for EEG that is made of flexible metal-coated polymer bristles. We examine various standard EEG paradigms, such as capturing occipital alpha rhythms, testing for event-related potentials in an auditory oddball paradigm and performing a sensory motor rhythm-based event-related (de-) synchronization paradigm to validate the performance of the novel electrodes in terms of signal quality. Our findings suggest that the dry electrodes that we developed result in high-quality EEG recordings and are thus suitable for a wide range of EEG studies and BCI applications. Furthermore, due to the flexibility of the novel electrodes, greater comfort is achieved in some subjects, this being essential for long-term use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
CRC Handbook of Chemistry and Physics
P, D. (1992) · Journal of Molecular Structure · doi:10.1016/0022-2860(92)85083-s · Cited by 9,329
Blind signal separation: statistical principles
Cardoso, J.-F. (1998) · Proceedings of the IEEE · doi:10.1109/5.720250 · Cited by 1,885
Identifying true brain interaction from EEG data using the imaginary part of coherency
Nolte, G., Bai, O., Wheaton, L., Mari, Z., Vorbach, S., & Hallett, M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.04.029 · Cited by 1,756
Scalp electrode impedance, infection risk, and EEG data quality
Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00533-2 · Cited by 1,005
Lotze, M., Montoya, P., Erb, M., Hülsmann, E., Flor, H., Klose, U., Birbaumer, N., & Grodd, W. (1999) · Journal of Cognitive Neuroscience · doi:10.1162/089892999563553 · Cited by 993
Skin impedance from 1 Hz to 1 MHz
Rosell, J., Colominas, J., Riu, P., Pallas-Areny, R., & Webster, J. G. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.4599 · Cited by 343
The Berlin brain-computer Interface: accurate performance from first-session in BCI-naive subjects
Blankertz, B., Losch, F., Krauledat, M., Dornhege, G., Curio, G., & Muller, K.-R. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923152 · Cited by 338
Single Trial Classification of Motor Imagination Using 6 Dry EEG Electrodes
Popescu, F., Fazli, S., Badower, Y., Blankertz, B., & Müller, K.-R. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000637 · Cited by 202
Self-citationA dry electrode for EEG recording
Taheri, B. A., Knight, R. T., & Smith, R. L. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90053-1 · Cited by 176
Cited by
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
EmotionMeter: A Multimodal Framework for Recognizing Human Emotions
Zheng, W.-L., Liu, W., Lu, Y., Lu, B.-L., & Cichocki, A. (2019) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2018.2797176 · Cited by 1,276
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
BCILAB: a platform for brain–computer interface development
Kothe, C. A., & Makeig, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056014 · Cited by 412
A multimodal approach to estimating vigilance using EEG and forehead EOG
Zheng, W.-L., & Lu, B.-L. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a98 · Cited by 424
Metadata
- Authors
- Grozea, C., Voinescu, C. D., & Fazli, S.
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2011-03-24
- Volume
- 8
- Issue
- 2
- Pages
- 025008
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2092447967
- Cited by
- 256
- References
- 19
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bristle-sensors—low-cost flexible passive dry EEG electrodes for neurofeedback and BCI applications. https://app.cochat.ai/papers/10.1088/1741-2560/8/2/025008
- The paper
- Grozea, C., Voinescu, C. D., & Fazli, S. (2011). Bristle-sensors—low-cost flexible passive dry EEG electrodes for neurofeedback and BCI applications. Journal of Neural Engineering. https://doi.org/10.1088/1741-2560/8/2/025008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.