The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Skin impedance from 1 Hz to 1 MHz
Abstract
The impedance of skin coated with gel but otherwise unprepared was measured from 1 Hz to 1 MHz at ten sites on the thorax, leg, and forehead of ten subjects. For a 1-cm/sup 2/ area, the 1 Hz impedance varied from 10 k Omega to 1 M Omega , which suggests that the bipotential amplifier input impedance should be very high to avoid common-mode-to-differential-mode voltage conversion. The 1-MHz impedance was tightly clustered about 120 Omega . The 100-kHz impedance was about 220 Omega , which suggests that the variation in skin impedance can cause errors in two-electrode electrical impedance tomographs.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Temporal changes in electrode impedance while recording the electrocardiogram with “Dry” electrodes
Geddes, L. A., & Valentinuzzi, M. E. (1973) · Annals of Biomedical Engineering · doi:10.1007/bf02407675 · Cited by 98
Characteristics of skin admittance for dry electrodes and the measurement of skin moisturisation
Yamamoto, Y., & Yamamoto, T. (1986) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441608 · Cited by 77
Skin-electrode impedance problems in electrocardiography
Berson, A. S., & Pipberger, H. V. (1968) · American Heart Journal · doi:10.1016/0002-8703(68)90138-5 · Cited by 45
Hary, D., Bekey, G. A., & Antonelli, D. J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326033 · Cited by 17
Cited by
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Ultrasound-Mediated Transdermal Protein Delivery
Mitragotri, S., Blankschtein, D., & Langer, R. (1995) · Science · doi:10.1126/science.7638603 · Cited by 791
Penetration of Metallic Nanoparticles in Human Full-Thickness Skin
Baroli, B., Ennas, M. G., Loffredo, F., Isola, M., Pinna, R., & Arturo López-Quintela, M. (2007) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5700733 · Cited by 464
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441666 · Cited by 450
Percutaneous Penetration Enhancers
(2005) · CRC Press eBooks · doi:10.1201/9781420039207 · Cited by 372
Metadata
- Authors
- Rosell, J., Colominas, J., Riu, P., Pallas-Areny, R., & Webster, J. G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1988
- Volume
- 35
- Issue
- 8
- Pages
- 649-651
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2115969310
- Cited by
- 343
- References
- 4
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.