In vivo reflectance of blood and tissue as a function of light wavelength
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Light reflectance from soft tissue has been utilized in noninvasive clinical measurement devices such as the photoplethysmograph and the reflectance pulse oximeter. Incident light on the skin travels into the underlying layers and is in part reflected back to the surface. This paper describes the reflectance of light from in vivo tissue for wavelengths in the range from 420 to 940 nm, based on photon diffusion theory and on experimental results from studies of 17 subjects. The results show a minimum reflectance and a peak sensitivity to the blood pulsations in the wavelength range from 510 to 590 nm. Skin pigmentation is seen to attenuate reflectance rather than altering the character of the modulation spectra. Based on the model introduced in this paper, the dependence of modulation spectra on mean blood fractional volume as well as wavelength is also described theoretically, and corroborated by further experimental data at 570 and 630 nm. At these latter wavelengths, the signal-to-noise ratio was calculated for the blood volume pulsation signal in the presence of physiological noise. The median for calculated ratios of reflectance modulation by blood pulsation and ratios of signal to noise between the two wavelengths were 13.1 and 7.5, respectively, for 93 sites in nine subjects. These results are seen to be consistent with the theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“The role of PPG wavelength in perfusion measurement has also been discussed by de Trafford and Lafferty (1984), Giltvedt et al (1984), Cui et al (1990) and Sandberg et al (2005).”
BackgroundMethodNon-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“For reflectance-mode PPG, the green wavelength produces greater signal amplitude and lower motion artifact than IR and red [69], [75]–[77].”
BackgroundWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“However, green-wavelength PPG devices are becoming increasingly popular due to the large intensity variations in modulation observed during the cardiac cycle for these wavelengths [7–9].”
BackgroundThe use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Metadata
- Authors
- Cui, W., Ostrander, L. E., & Lee, B. Y.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1990-06
- Volume
- 37
- Issue
- 6
- Pages
- 632-639
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2124264760
- Cited by
- 149
- References
- 1
- FWCI
- 2.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo reflectance of blood and tissue as a function of light wavelength. https://app.cochat.ai/papers/10.1109/10.55667
- The paper
- Cui, W., Ostrander, L. E., & Lee, B. Y. (1990). In vivo reflectance of blood and tissue as a function of light wavelength. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.55667
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.