The DOI matches its Crossref record.
Long-term unrestrained measurement of stride length and walking velocity utilizing a piezoelectric gyroscope
Abstract
Long-term monitoring of stride length and walking velocity is considered to provide useful information for making decisions on treatment of patients with gait disabilities. The purpose of this study was to develop a device with the following design criteria: lightweight, easy attachment, little hindrance to the natural gait pattern, sufficient memory to record for one day, and practicality in clinical use. The prototype consists of a piezoelectric gyroscope, which detects angular velocity of the thigh of one leg in the sagittal plane, and a microprocessor-based maximum/minimum detector/data logger of a cyclic analog signal associated with the gait cycle. The accuracy of the device was evaluated in 20 normal subjects, seven above-the-knee (A/K) amputees, and ten hemiplegic patients, and relative accuracy within +/-15% was obtained, except for two special cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814
Haghi, M., Thurow, K., & Stoll, R. (2017) · Healthcare Informatics Research · doi:10.4258/hir.2017.23.1.4 · Cited by 711
Assessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Metadata
- Authors
- Miyazaki, S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1997
- Volume
- 44
- Issue
- 8
- Pages
- 753-759
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2128416094
- Cited by
- 194
- References
- 0
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term unrestrained measurement of stride length and walking velocity utilizing a piezoelectric gyroscope. https://app.cochat.ai/papers/10.1109/10.605434
- The paper
- Miyazaki, S. (1997). Long-term unrestrained measurement of stride length and walking velocity utilizing a piezoelectric gyroscope. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.605434
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.